Newsroom
Pressemitteilungen
Aktuelles
Blog
Messen und Events
Newsletter
Karriere
Stellenangebote
Angebote für Schüler
Angebote für Studenten
Angebote für Berufserfahrene
Downloads
Engineering Apps
Engineering Daten
Engineering software tools
Produktbezogene Application Knowledge Base Artikel
Produktbezogene Dokumentation
Zertifikate und Erklärungen
Online Tools
EASY Product Finder
Antriebsauslegung
Maschinenlösung
CAD Konfigurator
M-n Kennlinien
Smart Conveyor Calculator
Kontakt
Lenze in Deutschland
Lenze weltweit
Kontaktformular
Deutschland (Germany)
Deutsch
English
Land wechseln
Produkte
IIoT
Steuerungen
Umrichter
Getriebemotoren
Motoren
Getriebe
Zubehör
Software
Lenze FAST Application Software
Lenze Selection
Lösungen
Systeme
Unsere Hardware
X4 Remote
Motion Control
IT meets OT
Automation
Sicherheitstechnik
Unsere Hardware
Unsere Software
NUPANO Open Automation Platform
OEE & Downtime Tracking
Maschinenvisualisierung
Engineering Suite
SMART Engineering Apps
Unsere Software
Unsere Brainware
Digital Solutions
Condition Monitoring
Digitaler Zwilling
Lenze Engineering Service
Lenze Performance Partner
Unsere Brainware
Systeme
Mechatronik
Mechatronic Competence Campus
Dezentrale Drive Packages
Energieeffizienz
Smart Conveyor Calculator
Mechatronik
Brand Labeling
Branchen
Automobilindustrie
Referenzen
Automobilindustrie
Batterieproduktion
Converting- und Druckindustrie
Referenzen
Converting- und Druckindustrie
Fahrzeug-Waschanlagen
Flughafenlogistik
Glas, Stein und Keramik
Holzbearbeitung
HVAC-R
Kältetechnik und Wärmepumpen
Lüftungstechnik und Ventilationstechnik
HVAC-R
Kunststoffindustrie
Kurier Express Paket
Lagerlogistik
Lösungen Regalbediengeräte
Lagerlogistik
Metallbearbeitung
Pumpen
Robotics
Textilindustrie
Referenzen
Textilindustrie
Verpackungsindustrie
Referenzen
Verpackungsindustrie
Branchen
Referenzen
Converting und Druckindustrie
BST
Donghang Graphic Technology Inc.
DURST Group
D.W. Engineers
GIC
MAAN Engineering
Mendel RG Systems
Nikelman Druckmaschine
Relinquo Automation Pvt. Ltd.
Suddha Machineries and Industries PVT LTD
Converting und Druckindustrie
Flughafenlogistik
Kurier Express Paket
Lagerlogistik
bonArea
Stöcklin Hochregallager
Vectron
Witron Lagerlogistik
Lagerlogistik
Textilindustrie
Dilmenler
Gilbos
MBK und DMS Dilmenler
Menzel Kompaktwaschanlage
Monforts Textilmaschinen
Nomaco Faservliesmaschinen
nsc.n schlumberger
Picanol Webmaschinen
Pro-SMH
Texpro
Trigema und Xetma Vollenweider
Zimmer Austria
Textilindustrie
Verpackungsindustrie
Citus Kalix Verpackungsmaschinen
DMK
Fricke Abfülltechnik
Kletec Eierverarbeitungsmaschinen
MAKRO MAKINA
Mondini
PAYPER
TechNikkels
Wolf Verpackungsmaschinen
XOX Retrofit Extruder
Verpackungsindustrie
Weitere Branchen
Bauer
HEGLA New Technology
KABTEC Prüfanlagen
Lisec
MFL
Schelling Sägezentrum
Weinig Grecon
Weitere Branchen
Referenzen
Lösungen
Service
Aftersales Service
Training
Präsenz Training
E-Learning
Online-Training
Training
Engineering service
Cyber Security
Cyber Security Statements
Cyber Security
Software Downloads
EASY Engineering Tools
Engineering Apps
Engineering Daten
Software Downloads
Knowledge Base
Application Knowledge Base
Produktbezogene Dokumentation
Unternehmensbezogene Dokumentation
Knowledge Base
Product-Lifecycle-Management
X4 Remote Support
Service
Support
Unternehmen
Unternehmensgruppe
Unser Ansatz
Qualitätsversprechen
Industrie 4.0
Unser Ansatz
Unsere Verantwortung
Verantwortung für Mitarbeiter
Gesellschaftliches Engagement
Hans und Clara Lenze Stiftung
Unsere Verantwortung
Unsere Kultur
Unser Management
Unsere Historie
Historie Lenze
100 Jahre Elisabeth Belling
Unsere Historie
Unternehmensgruppe
Globale Präsenz
Afrika
Lenze in Südafrika
Afrika
Amerika
Lenze in Brasilien
Lenze in Kanada
Lenze in Mexiko
Lenze in den USA
Amerika
Asien
Lenze in China
Lenze in Indien
Lenze in Korea
Lenze in den Philippinen
Lenze in Singapur
Lenze in der Türkei
Asien
Nordeuropa
Lenze in Dänemark
Lenze in Finnland
Lenze in Schweden
Nordeuropa
West- und Mitteleuropa
Lenze in Belgien
Lenze in Deutschland
Lenze in Estland
Lenze in Frankreich
Lenze in Lettland
Lenze in Litauen
Lenze in Österreich
Lenze in den Niederlanden
Lenze in Polen
Lenze in der Schweiz
Lenze im Vereinigten Königreich
West- und Mitteleuropa
Osteuropa
Lenze in Bulgarien
Lenze in Mazedonien
Lenze in Rumänien
Lenze in Russland
Lenze in Serbien
Lenze in der Slowakei
Lenze in Slowenien
Lenze in Tschechien
Lenze in Ungarn
Osteuropa
Südeuropa
Lenze in Italien
Lenze in Kroatien
Lenze in Mazedonien
Lenze in Spanien
Südeuropa
Globale Präsenz
Nachhaltigkeit
WEEE-Richtlinie
Nachhaltigkeit
Compliance
Newsroom
Presseinformationen Lenze-Gruppe
Aktuelles
Blog
Messen und Events
Newsletter
Newsroom
Karriere
Stellenangebote
Offene Stellen Deutschland
Offene Stellen in Polen
Offene Stellen Benelux und Vereinigtes Königreich
Offene Stellen Schweiz
Offene Stellen Tschechien
Offene Stellen USA
Offene Stellen China
Stellenangebote
Arbeiten bei Lenze
Wir sind Lenze
Angebote für Schüler
Ausbildung
Duales Studium
Berufsorientierung
Angebote für Schüler
Angebote für Studenten
Angebote für Berufserfahrene
Karriere
Global Procurement
Unternehmen
Deutschland (Germany)
Deutsch
English
Land wechseln
Home
Application Knowledge Base
Artikel
- Versions-Historie ECS Application (HW und B-SW) ≤ V8.3
- Version history ECS Application (B-SW and Hardware) up to V8.3
Operating software (B-SW) Application V8.3 (serial version)
Function extensions:
Fail-QSP fault response added to brake relay monitoring (C0602=4)
(as of B-SW V8.3)
CAN parameter data channel (SDO) - adapted parameter data length
(as of B-SW V8.3)
Free CAN-PDO: Monitoring of received CAN telegrams removed
(as of ECS B-SW V8.3, SPLC V8.0)
Hiperface absolute value encoder, initialisation extended for encoder types SKx36, SRx50V2, SFx60, SEK52, DME5000
(as of B-SW V8.3)
Loading the default setting for the OPERATING SYSTEM and processing the code initialisation list for the application software with C0002=2
(as of B-SW V8.3)
Eliminated function restrictions:
AIF communication - Status bits 8..15 of AIF_Management_IO always equal to zero
(eliminated as of B-SW V8.3)
AIF interface - CAN monitoring using toggle bit for write access to C2120 - Function not reliable
(eliminated as of B-SW V8.3)
Analog input (AIN1) - Sign reversal on exceeding 12 V
(eliminated as of B-SW V8.3)
Operation with Profibus 2133, status bit for n=0 not processed
(eliminated as of B-SW V8.3)
Elapsed-hour meter (C0178) and power-on time meter (C0179) exhibit deviation of 20 s/h
((eliminated in Drive PLC, as of ECS B-SW V8.3, SPLC as of V8.0)
CANaux - SDO jobs received in the Stopped CAN status should be rejected but are not
(eliminated as of B-SW V8.3)
Download with L-force Loader via parameter channel 2 - Abort on change of CAN node address (C0350)
(eliminated as of B-SW V8.3)
Download with L-force Loader via system bus CANaux (X14) - Abort on change of CANaux node address (C2450)
(eliminated as of V8.3 with *.pdb from GU16)
Downloading parameters with the card module - PR0 error when device sizes differ
(eliminated as of B-SW V8.3)
Downloading projects - Queued fault message for application (L_FWM) not reset
(eliminated as of B-SW V8.3)
Electrical shaft with CAN2_IO, CAN3_IO in sync mode - Torque peaks and noise due to temporal offset after PLC stop/start
(eliminated as of Drive PLC, ECS B-SW V8.3, SPLC as of V8.0)
Field weakening and operation of asynchronous motors in generator mode - Overcurrent fault message
(eliminated as of B-SW V8.3)
GDC menu for CAN3-IN - Wrong display codes
(eliminated with *.pdb from GU16)
Multi-axis synchronisation via CAN - Torque peaks and noise
(eliminated as of Drive PLC, ECS B-SW V8.3, SPLC as of V8.0)
Set home - Incorrect actual position when mains power is switched on after multiple write operations using code C0098
(eliminated as of B-SW V8.3)
SD7 trip on some Hiperface absolute value encoders SKM36/SKS36
(eliminated as of V8.0 on 9300ES/EP/EK, ECS as of B-SW V8.3)
Touch probe TP1 (DI1) does not respond after mains switching and with CAN synchronisation
(eliminated as of B-SW V8.3)
Mains switching has to be performed after loading default setting in order for touch probe, homing switch (DI2) to be detected
(eliminated as of B-SW V8.3)
Function restrictions:
Automatic switching frequency change-over (C0018=2) - Torque peak at moment of change-over
Operation with Profibus 2133, status bit for n=0 not processed
(no plans to make changes)
Field weakening and operation of asynchronous motors in generator mode - Overcurrent fault message
(no plans to make changes)
AIF_wControl system variable without function
-(new) Systembus CANaux (X14) - Sync transmit cycle not as set under C2469, but round about 65s (use older B-SW <>
Error when reading out a parameter via L_ParRead()
Error when accessing parameters via L_ParRead()/L_ParWrite() after TimeOut
Operating software (B-SW) Application V8.0
Additional functions:
Reducing the rated motor current
(from B-SW V8.0)
Display of the resolver signal quality
(from B-SW V8.0)
Zero pulse evaluation of the master frequency input
(from B-SW V8.0)
Boot-up telegram
(from B-SW V8.0)
L_CanSetFilter function block
(from B-SW V8.0)
Characteristics selection for KTY motor temperature sensors of MCS motors
(from B-SW V8.0)
Node address of the system bus interface X14 (CANaux) can also be set via DIP switch
(from B-SW V8.0)
New tree structure in the parameter set menu
(from B-SW V8.0)
Support of the new AIF modules ¨CANopen¨ and ¨DeviceNet¨
(from B-SW V8.0)
GDC, menu structure and texts in the pdb files revised with regard to usability aspects (V2.0/1.2/8.0/3.0 - xP/xM/xA/xE onwards)
(from B-SW V8.0)
Remedied function restrictions:
Display bit of the CANaux state ¨BusOff¨ cannot be reset
(remedied from B-SW V8.0)
AP1 trip after project download
(behoben ab B-SW V8.0)
CAN-AUX interface is not supported by L_ParRead/L_ParWrite
(remedied from B-SW V8.0)
CAN2 and CAN3 are not sent sync controlled
(remedied from B-SW V8.0)
Codes for synchronising the drive are missing in the keypad menu
(remedied from B-SW V8.0)
Data of the sync telegram too long
(remedied from B-SW V8.0)
Continuous sending of SDO telegrams when C2118 has been changed
(remedied from B-SW V8.0)
DDS download error in case of programs larger 256 kB
(remedied from B-SW V8.0)
FP interface does not send data after Trip Reset
(remedied from B-SW V8.0)
Keypad password also inhibits CAN-AUX and FIF-CAN
(remedied from B-SW V8.0)
Node guarding event cannot be reset
(remedied from B-SW V8.0)
PLC target system sends a boot-up event during download
(remedied from B-SW V8.0)
PLC target system sends sync telegrams in millisecond cycles
(remedied from B-SW V8.0)
PLC target system denies write access to codes
(remedied from B-SW V8.0)
¨float Cycle-T¨ trip cannot be reset
(remedied from B-SW V8.0)
Changing the motor control mode results in a trip
(remedied from B-SW V8.0)
Numerical overflow of REAL variables does sporadically not activate a trip
(remedied from B-SW V8.0)
Function restrictions:
FAQ:
L_ParRead/L_ParWrite with old DriveLib 0201 and use of the ECS operating software 8.0 - Which aspects are to be observed?
Operating software (B-SW) Application V7.4
Additional functions:
Remedied function restrictions:
Change of rotor displacement angle after change of speed feedback
(remedied from B-SW V7.4)
Output of rotor position for multipole resolver
(remedied from B-SW V7.4)
Evaluation of the zero pulse of the position feedback
(remedied from B-SW V7.4)
Motor model calculation for the asynchronous motor
(remedied from B-SW V7.4)
Communication reset leads to an activation of the free CAN objects
(remedied from B-SW V7.4)
No value for MCTRL_dnActIncLastScan in case of splitted feedback
(remedied from B-SW V7.4)
NMT as response to remote request only suppressed at the master
(remedied from B-SW V7.4)
Number of pole pairs of resolver is also evaluated with TTL or SIN/COS feedback system
(remedied from B-SW V7.4)
QSP behaviour when reaching the torque limit Tmax during QSP ramp
(remedied from B-SW V7.4)
Controller sporadically does not supply current at controller enable
(remedied from B-SW V7.4)
Task Overrun when the LenzeCanDrv.lib library is used
(remedied from B-SW V7.4)
Operating software (B-SW) Application V7.1
Additional functions:
Remedied function restrictions:
Exception handling: Reset of the warning after task overrun
(remedied from B-SW V7.1)
Faulty parameter setting of the devices ex works (3/2005...7/2006 only)
(remedied)
Changeover error configuration
(remedied from B-SW V7.1)
Operating software (B-SW) Application V7.0
Additional functions:
Selecting any number of increments for absolute value encoders
(from B-SW V7.0)
C0032 - Gearbox factor numerator
(from B-SW V7.0)
Extension of the selection list for encoders
(from B-SW V7.0)
Extension of the SinCos encoder monitoring
(from B-SW V7.0)
Extension of the AIF_IO_Management system block
(from B-SW V7.0)
Motor phase monitoring
(from B-SW V7.0)
Monitoring of the rotor position adjustment
(from B-SW V7.0)
Remedied function restrictions:
If errors of the message or warning type occur several times, the error remains active even if the causes of the malfunction have been removed
(remedied from B-SW V7.0)
Brake monitoring when motor cables longer than 30m are used
(remedied from B-SW V7.0)
C0006 can only be changed if the PLC target system is stopped
(remedied from B-SW V7.0)
C1192/1 is reset to 0 after program download
(remedied from B-SW V7.0)
CAN-Telegramme werden nicht mehr empfangen
(remedied from B-SW V7.0)
Torque limit in case of quick stop (QSP)
(remedied from B-SW V7.0)
Errors of the Fail-QSP type - the error message is repeatedly stored in the fault memory
(remedied from B-SW V7.0)
Error messages of the Fail-QSP type are stored in the fault memory with a wrong offset
(remedied from B-SW V7.0)
L_FWM function module
(remedied from B-SW V7.0)
No controller inhibit in case of a control reset
(remedied from B-SW V7.0)
LU message generates task overrun
(remedied from B-SW V7.0)
PEr error after TRIP reset
(remedied from B-SW V7.0)
Default setting under code C1121 does not correspond to the product documentation
(remedied from B-SW V7.0)
Default setting value for C1122 is too low
(remedied from B-SW V7.0)
Wrong values in temporary codes
(remedied from B-SW V7.0)
SYSTEM_bPLCResetAndRun without function
(remedied from B-SW V7.0)
Selection of RAM blocks (C0506) with wrong display value
(remedied from B-SW V7.0)
Keypad: Wrong display after TRIP reset
(remedied from B-SW V7.0)
Operating software (B-SW) Application V6.7
Additional functions:
Remedied function restrictions:
Operating software (B-SW) Application V6.6
Additional functions:
Emergency message via AIF
(from B-SW V6.6)
Extension of the AIF_IO_Management for the DSP402 device profile
(from B-SW V6.6)
Remedied function restrictions:
Writing code C0058 (pdb ESCxA)
(remedied from B-SW V6.6)
Task overrun caused by impermissible current controller values
(remedied from B-SW V6.6)
Charging routine of the ECSxA
(remedied from B-SW V6.6)
Oscillation of the drive during field weakening operation
(remedied from B-SW V6.6)
KTY temperature sensor characteristic (detection of the motor temperature)
(remedied from B-SW V6.6)
Peak currents during operation
(remedied from B-SW V6.6)
Check sum error during program download does not lead to an error
(remedied from B-SW V6.6)
Reset (original) does not delete Application RAM 1and 2
(remedied from B-SW V6.6)
Task overflow (overrun) in case of projects without PLC_PRG
(remedied from B-SW V6.6)
Transmitting cycle time of the process data channels CAN2 and CAN3 is doubled
(remedied from B-SW V6.6)
Operating software (B-SW) Application V6.5
Additional functions:
Card Download Module
(from B-SW V6.5)
Remedied function restrictions:
L_FWM function module
(remedied from B-SW V6.5)
SD7 and SD8 are not entered into the history buffer
(remedied from B-SW V6.5)
Units of some codes are not displayed correctly in GDC
(remedied from B-SW V6.5)
PEr error after reset
(remedied from B-SW V6.5)
Undefined signals at encoder connection X8 (master frequency output)
(remedied from B-SW V6.5)
Ixt device temperature monitoring releases too early (OC5)
(remedied from B-SW V6.5)
DFIN, varying values
(remedied from B-SW V6.5
L_FWM function module - heatsink temperature monitoring (OH)
L_FWM function module - Message no longer active - pulse inhibit remains active
Operating software (B-SW) Application V3.0:
(Initial field test version)
Additional functions:
Remedied function restrictions:
No DFOUT signals after starting the PLC
(remedied from B-SW V3.0)
Resolver evaluation improved
(remedied from B-SW V3.0)
Function restrictions:
Actual speed value display C0051 also varies during standstill
Sine/cosine encoder and error message overrun after rotor position adjustment
(remains inside B-SW)
Version history
(Intranet supplement)
, topics published Lenze internally only
Download 9300, ECS, assignment of firmware and hardware versions
, operating software (B-SW), application software (A-SW)
URL for linking this AKB article:
https://www.lenze.com/en-de/go/akb/200910598/1/
Metadaten
Taxonomy: ECSxA application , ECSxE power supply module , ECSxK capacitor module , ECSxM motion , ECSxP position and shaft , ECSxS speed and torque , ECS servo inverters
AKB-ID: 200910598
Last update: 2023/09/14
Category: Versions-Informationen
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.
©
Standort ändern
Impressum
Datenschutz
Nutzungsbedingungen
Kontaktformular