AIF interface - CAN monitoring using toggle bit for write access to C2120 - Function not reliable (eliminated as of OPERATING SYSTEM V8.3)

Eliminated as of:
ECS Application OPERATING SYSTEM  as of V8.3

Behaviour of the new version?
The AIF communication module and toggle bit can now be used to monitor CAN communication.



Which products are affected?
ECS Application OPERATING SYSTEM <= V8.0

What happens?
Monitoring of CAN communication (AIF interface) with the toggle bit cannot be relied upon for write access to C2120.

When does the problem occur?
In the event of write access to C2120.

Diagnostics options?
None.

Short-term measures/recommendations?
Use other mechanisms to monitor CAN communication, e.g. CE0, node guarding.

Evaluation:
Other mechanisms are available to monitor CAN communication.

Published with Service Message No. 2010/32

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201011315/1/