Remedied from:
ECS axis module V7.1,
all versions (ECSxS, ECSxP, ECSxM, ECSxA)
Behaviour of new version?
In the previous version of the operating system the error has not been set after a reconfiguration of the reaction on an active EEr warning. Now the error configuration can also be reset in case of an active error. The Trip will be triggered.
Which products are affected?
ECS axis module V7.0,
all versions (ECSxS, ECSxP, ECSxM, ECSxA)
What happens?
An EEr message (C0581 = 1) is activated, and with code C581 the configuration is set to TRIP (C0581 = 0). The TRIP is not entered, and the motor is rotating.
When does the problem occur?
The problem occurs, when during an activated error (C581= 1 'message'), whose cause has not been eliminated yet, the error configuration of this message is set to TRIP (C0581 = 0).
Short-term message / recommendations?
The error configuration in C 581 is only allowed to be changed when there is no EEr error.
Evaluation:
We detected this behaviour during and internal test. In practice this kind of setting is unusual. Generally, an error configuration is not modified in case of an error.
Published with service message No. 2006/17 and 2006/23