Mains switching has to be performed after loading default setting in order for touch probe, homing switch (DI2) to be detected (eliminated as of OPERATING SYSTEM V8.3)

Eliminated as of:
ECS Application OPERATING SYSTEM  as of V8.3

Behaviour of the new version?
The touch probe edge at the homing switch (DI2) is now detected correctly after loading the default setting; intermediate mains switching is not required.



Which products are affected?
ECS Application OPERATING SYSTEM  <= V8.0

What happens?
Drive does not respond to the signal at the touch probe input.

When does the problem occur?
After loading the default setting, if intermediate mains switching is not performed.
The problem affects the Posi&Shaft application software in particular and occurs frequently during homing.

Diagnostics options?
Generate edge at touch probe input DI2: Drive does not respond as expected.

Short-term measures/recommendations?
Perform mains switching once after loading the default setting. After this, touch probe evaluation functions without errors.

Evaluation:
No particular relevance for practical applications, as mains switching is carried out as standard during commissioning.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201010968/1/