Corrected from:
-
Behavior of the new version:
-
Description of behavior:
During automatic parameterization after selecting a motor in the 'Select motor' dialog, error messages appear when writing to current motor control parameters 0x2942:005 and 0x2942:007.
Conditions under which the behavior occurs:
The error messages described above occur when
- The EASY Starter or PLC Designer is connected online to an inverter from the i5xx cabinet, protec, motec, or i650 motec series and
- the firmware of the inverter in question supports current motor control parameters 0x2942:005 and 0x2942:007, and
- a motor has been selected for which a control mode other than "Sensorless control (SL-PSM) [3]" or "Sensorless control (SLSM-PSM) [8]" is preset.
Affected products:
EASY Starter from V1.29
PLC Designer from V4.1
Short-term measures, recommendations, assessment:
The error messages do not lead to any malfunction in the operation of the inverter and can be tolerated as long as the preset control mode is used.
[Automatic Translation]