Newsroom
Press releases
Aktuelles
Blog
Trade fairs and events
Newsletter
Careers
Current vacancies
Experienced Professional
Downloads
Engineering apps
Engineering data
Engineering Software tools
Product-related Application Knowledge Base articles
Product-related documentation
Certificates and declarations
Online Tools
EASY Product Finder
Drive Sizing
Machine Design
CAD Configurator
M-n curves
Smart Conveyor Calculator
Contact
Lenze in Germany
Lenze worldwide
Contact form
Deutschland (Germany)
Deutsch
English
Change country
Products
IIoT
Controllers
Inverters
Geared motors
Motors
Gearboxes
Accessories
Software
Lenze FAST Application Software
Lenze Selection
Solutions
Systems
Our hardware
X4 Remote
Motion Control
IT meets OT
Automation
Functional safety
Our hardware
Our software
NUPANO Open Automation Platform
OEE & Downtime Tracking
Machine Visualization
Engineering Suite
SMART Engineering apps
Our software
Our brainware
Digital Solutions
Condition monitoring
Digital Twin
Lenze Engineering services
Lenze Performance Partner
Our brainware
Systems
Mechatronics
Mechatronic Competence Campus
Decentralized Drive Packages
Energy efficiency
Smart Conveyor Story
Mechatronics
Brand Labeling
Industries
Automotive industry
References
Automotive industry
Battery Production
Converting and printing industry
References
Converting and printing industry
Vehicle washing
Airport logistics
Glass, stone and ceramics
Wood working
HVAC-R
Refrigeration engineering and heat pumps
Ventilation equipment
HVAC-R
Plastics industry
Courier Express Parcel
Warehouse logistics
Solutions Storage and retrieval machine
Warehouse logistics
Metalworking
Pumps
Robotics
Textile industry
References
Textile industry
Packaging industry
References
Packaging industry
Industries
References
Converting and printing industry
BST
Donghang Graphic Technology Inc.
DURST Group
D.W. Engineers
GIC
MAAN Engineering
Mendel RG Systems
Nikelman Printing press
Relinquo Automation Pvt. Ltd.
Suddha Machineries and Industries PVT LTD
Converting and printing industry
Airport logistics
Courier, Express & Parcel
Warehouse logistics
bonArea
Stöcklin High-bay warehouse
Vectron
Witron Warehouse logistics
Warehouse logistics
Textile industry
Dilmenler
Gilbos
MBK and DMS Dilmenler
Menzel Compact washer
Monforts Textile machine
Nomaco Nonwoven machines
nsc.n schlumberger
Picanol Weaving machines
Pro-SMH
Texpro
Trigema and Xetma Vollenweider
Zimmer Austria
Textile industry
Packaging industry
Citus Kalix Packaging machine
DMK
Fricke Abfülltechnik
Kletec Egg processing machines
MAKRO MAKINA
Mondini
PAYPER
TechNikkels
Wolf Packaging machines
XOX Retrofit extruder
Packaging industry
Further industries
Bauer
HEGLA New Technology
KABTEC Test systems
Lisec
MFL
Schelling Sawing center
Weinig Grecon
Further industries
References
Solutions
Services
Aftersales services
Training
On-site training
E-Learning
Online training
Training
Engineering services
Cyber Security
Cyber Security Statements
Cyber Security
Software downloads
EASY Engineering tools
Engineering Apps
Engineering data
Software downloads
Knowledge base
Application Knowledge Base
Product-related documentation
Company-related documentation
Knowledge base
Product-Lifecycle-Management
X4 Remote Support
Services
Support
Company
Group of companies
Our approach
Promise of quality
Industry 4.0
Our approach
Our responsibility
Employee responsibility
Social responsibility
Our responsibility
Our corporate culture
Our management
Our history
History Lenze
100 years Elisabeth Belling
Our history
Group of companies
Global presence
Africa
Lenze in South Africa
Africa
Americas
Lenze in Brazil
Lenze in Canada
Lenze in Mexico
Lenze in the Americas
Americas
Asia
Lenze in China
Lenze in India
Lenze in Korea
Lenze in the Philippines
Lenze in Singapore
Lenze in Turkey
Asia
Northern Europe
Lenze in Denmark
Lenze in Finland
Lenze in Sweden
Northern Europe
Western and Central Europe
Lenze in Belgium
Lenze in Germany
Lenze in Estonia
Lenze in France
Lenze in Latvia
Lenze in Lithuania
Lenze in Austria
Lenze in the Netherlands
Lenze in Poland
Lenze in Switzerland
Lenze in United Kingdom
Western and Central Europe
Eastern Europe
Lenze in Bulgaria
Lenze in Macedonia
Lenze in Romania
Lenze in Russia
Lenze in Serbia
Lenze in Slovakia
Lenze in Slovenia
Lenze in Czech
Lenze in Hungary
Eastern Europe
Southern Europe
Lenze in Italy
Lenze in Croatia
Lenze in Macedonia
Lenze in Spain
Southern Europe
Global presence
Sustainability
WEEE Directive
Sustainability
Compliance
Newsroom
Press releases Lenze Group
Topicals
Blog
Trade fairs and events
Newsletter
Newsroom
Careers
Current vacancies
Current vacancies Germany
Current vacancies in Poland
Current vacancies Benelux and UK
Current vacancies Switzerland
Current vacancies USA
Current vacancies China
Current vacancies
Working at Lenze
We are Lenze
Offers for students
Experienced professionals
Careers
Global Procurement
Company
Deutschland (Germany)
Deutsch
English
Change country
Home
Application Knowledge Base
Article
Versions-History 8400 HighLine frequency inverters
Version V21.02.00.0000
Function extensions:
not existing
Solved function restrictions:
Constant speed during Velocity-Override (nSpeedOverride_a)
Timeout with empty "retain memory" / Error message "dF50"
Function restrictions:
not existing
Difference descriptions:
not existing
Version V21.01.00.0000
Function extensions:
not existing
Solved function restrictions:
Increasing the value range of C12 and C13
Difference descriptions:
not existing
Version V21.00.00.0000
Function extensions:
Initialising the brake resistor utilisation
Automatic oscilloscope start after mains connection
Further functions in L_Arithmetic_3 to L_Arithmetic_5
Optimising SLPSM control
Solved function restrictions:
No connection via remote maintenance router
Auto-start lock after undervoltage error
Sporadic error message DF21 (BU watchdog)
Error when loading the parameters from copied memory modules
Difference descriptions:
not existing
Version V20.00.00.0000
Function extensions:
New memory modules supported
Solved function restrictions:
"L_Compare_X"and "L_ComparePhi_X" with input value 0x8000 or 0x80000000
Difference descriptions:
not existing
Version V18.00.00.0000
Function extensions:
Load default setting without communication parameters
Extension of initial keypad screen
Torque limitation with HighLimit and LowLimit possible
Solved function restrictions:
Motor stalling with SLVC and high output frequency
Error message dF25 (CU RCOM) with PPI without movement
Error message SD15 in the event of an excessive input frequency at DI6 + DI7
Delayed start of Ethernet Powerlink control nodes (slaves)
Difference descriptions:
not existing
Version V17.00.00.0000
Function extensions:
not existing
Solved function restrictions:
Ck10 error message no longer occurs
Absolute modulo positioning too far by one cycle
Difference descriptions:
not existing
Version V16.02.00.0000
Function extensions:
not existing
Solved function restrictions:
Overwriting of the reference start speed C01224/1
Difference descriptions:
not existing
Version V16.01.00.0000
Function extensions:
not existing
Solved function restrictions:
Incorrect triggering of An01: AIN1_I < 4 mA or An02: AIN2_I < 4 mA
Difference descriptions:
not existing
Version V16.00.00.0000
Function extensions:
Tn field weakening controller C578: Value range has been increased
L_DigitalLogic: 2 additional logic functions
LS_RetainData: Additional parameters for retain data access
LS_ParReadWrite: Read value remains optionally pending
Max. position controller system deviation can be extended from 65536 inc. to 2^31-1 inc.
Actual speed-based standstill detection for QSP with position control
'Ready to operate' status has been added to MCK
Operating mode selection via profile number has been extended by 'Position follower' and 'Normal stop'
Diagnostics of activated SW limits and HW limit switches via C1247
Extension of MCK diagnostic word C1247 for 'Max. speed is pending' status
Option: Extended profile linkage by means of overchange
Display parameter C1248/1 for current homing step
Overcurrent monitoring (overload monitoring) OC18
Device can transmit process data with individual sync
Hysteresis for nact detection can be set under code C0025/1
Elapsed-hour meter and power-on time meter are always displayed in case of 24-V supply
L_ConvAP, LConvPP: Faulty remainder consideration
Optimisation of the motor phase failure monitoring function
L_MFAIL: Acceleration and retrigger time up to a minimum of 0ms possible
Lower limit of C091 (motor cosine phi) has been adapted
Slip compensation for VFCplus does not work after downloading parameters
Display: Speed limitation reached
Display code C920/x 'Rated current' and 'Increased rated current'
V/f emergency operation in case of open circuit of HTL encoder
Additional error messages of reaction type 'Information'
Solved function restrictions:
Unstable field weakening control if C578<16ms
No PS03 info when replacing memory module with compatible parameter sets
Oscilloscope does not trigger in the case of digital signals and "Value change" trigger mode.
Flying restart circuit does not work in the event of a short-time undervoltage
Rated device currents are slightly too low
SLPSM: Current fluctuations in the controlled range
L_DFSet: Angle correction via polynomial is permanently inactive after bSetActIntegrator=TRUE
Vibrations with SLPSM if fdmax=C59 is higher than 650Hz
Incorrect unit of display parameters C837/20+28 of L_PhaseIntK
Incorrect unit of L_SRFG inputs in FB Editor display
Incorrect calculation of max. traversing distance C1213/1 and positioning accuracy C1210/5
Position controller cannot be deactivated via C1218/0 bit7 as expected
Clamp peak current limitation for SC from 4kW
SW limit position monitoring does not respond in homing modes 10/11 + 12/13
SW limit positions are not effective for travel ranges < 32768inc
Acceleration in the case of a position-controlled QSP with an initial following error
Difference descriptions:
not existing
Version V15.01.00.0000
Function extensions:
Extension of the MCK diagnostic parameters
Revision of the quick stop function
Automatic switch-over to V/f without encoder as emergency operation
Installation of CAN PDO 4
HTL 4-fold evaluation
Solved function restrictions:
Calculation of the speed controller parameters during motor identification
Limitation of the output frequency to C910
SC ASM: slip calculation from nameplate is incorrect
Reversing process in linear profile generation phase ignores ramp abort
User LED is working with "Optical tracking"
Offset of 1ms in the setpoint MCK.nSpeedSet_v in the case of quick stop
MCK setpoints not increment-precise in the case of QSP
Difference descriptions:
not existing
Version V14.00.00.0000
Function extensions:
Re-establishment of the pole position for PSM without an encoder with absolute position
Deletion of the reference information at the homing start
Setting or activation of the maximum jerk of traversing profiles
Following error generation at controller inhibit received C1215/3>0
Measurement of the distance between the home mark/limit switch and TP/MP
Extension of the homing modes by 4 (>_Rp__TP)
Setpoint processing for SC-ASM and SC-PSM
Completion of profile traversing when the profile has already reached the target
Extension of the Id8 error message: speed sensor not set
Extension of the dH70 error message: ControlUnit does not comply with BaseUnit
Extension of the brake chopper control
Parameter set transfer with the keypad
Entry of texts in the keypad
Display of bit texts in the keypad.
New error tripping with regard to pole position identification
Increase of the maximum current limit at a fixed switching frequency of 4kHz for a power of 30kW, 37kW, and 45kW
Motor parameter identification at switching frequency of 8kHz
1.1.3. Extension of the process display for the active output current and apparent output current
SLPSM for application reference frequency C59 > 650Hz
Transferring the CAN address switch to MCI module
Solved function restrictions:
Field/field weakening control for SC-ASM motor control
L_DFSet_1 error correction
L_SwitchPoint_1, L_SwitchPointPar_1: Incorrect scaling of the dead time
Ck10 error at profile start and override
Incorrect home position in the ’SetRef‘ ref. mode and in automatic brake operation
C1301/x target position in units for PosTeach and mains switching is not correct
In the case of a profile change, profile parameters are not complied with in the deceleration phase
SC-PSM jitters at high output speeds (> approx. 700Hz)
Profinet station name cannot be written
Id7 error in the case of a parameter set changeover with a definable list
Operation of an asynchronous machine with a very high slip speed not possible
No pulse inhibit after expiry of the hold time set for the manual DC injection brake with C142= 0
SLVC: OC1/OC11 error if fd>650Hz
VFC: Slip compensation at fd>650Hz
Torque accuracy if no KTY is available
SLVC/VFC: Apparent current display C054 jitters at f = 0 Hz
"Reset error" of a short circuit disconnection (OC1)
Speed step change after switching on the BaseUnit
After the parameter change-over (LS_WriteParamList), the motor does not run correctly
Unexpected acceleration at high speeds in SC-ASM
In the case of a profile change during a deceleration phase, profile parameters are not maintained
Profinet station name cannot be written
Operation with fout ≥ 650Hz causes OC11 error
Following error is deleted at controller inhibit
M-feedforward control unstable if the sensitivity of setpoint feedforward control is ≤12 bits
Difference descriptions:
not existing
Version V13.01.00.0000
Function extensions:
not existing
Solved function restrictions:
not existing
Difference descriptions:
not existing
Version V13.00.00.0000
Function extensions:
L_DFSet: external angle error correction
Additional process input bVfcEcoDisable
Additional process output bLimSpeedTorquemodeOn
Additional process output nVoltageAngleAct
Display parameter C162/1 for subject area +Id of the current error menu
AC drive profiles speed and speed and torque actuation with EtherNet/IP™
Solved function restrictions:
Modulo positioning is sporadically not executed
Incorrect scaling of the speed controller parameters if C059≥650Hz
No keypad texts for bit codes
ASM does not start up in SC-ASM if C095≈C022
No error response in the case of repeated activation of the limit switch in "position follower" operating mode
Incorrect feedforward control while releasing the brake when the M-storage is carried out
Current dips at fswitch
Sporadic motor phase error before operation
C002 reports 'OFF/complete‘ in spite of Id4 error during motor parameter identification
Switching hysteresis for device fan too low
In the case of download, C653/1 is overwritten with the value from C2314/1
Incorrect display of the interior temperature CU C062
Not all parameters selected in C517 can be viewed in the keypad user menu.
Unexpected rotating direction at start of PC manual control
Process setpoint interfaces in spite of operation via PC manual control
Ethernet Powerlink synchronisation not possible
Quantisation of the M-feedforward control with a correlation of J and t_acc
Torque limitation takes effect in the case of QSP
Brake chopper threshold is not adapted depending on C173
Difference descriptions:
not existing
Version V12.00.00.0000
Function extensions:
Forwarding of residual values within FBs
If the machine parameters are altered, reset bHomePosAvailable
Functional improvements at the L_DFSET_1
Support of EtherNet-IP fieldbus modules
Status bit for 'S-shape active' at L_MckStateInterface
Sensitivity threshold for the transfer of the actual speed as setpoint
Setpoint retention in the MCK
Position conversion - L_ConvUnitsToIncr_1
Extension of the L_Curve_3 by the tensile force characteristic function
Counter for STO, DigIn CINH, and IMP after mains connection
Automatic calculation of the current and field controller parameters
Speed limitation to 0rpm if bTorqueModeOn=TRUE
Torque limitation for bTorqueModeOn=TRUE
Starting value C122 for motor overload according to U_L and U_R specification
Automatic detection SM or ASM from motor parameters
Extension of the position encoder selection C490
Parallel control of brake choppers in DC-bus connection
CAN gateway for forwarding SDO requests via MCI
Adjustable delay time for IMax status
Extension of C199 to 5x32 bytes for device identification
Logbook read interface for the control or HMI
User level keypad selectable in C001
Extension of the acceleration feedforward control
Oscilloscope function
LS_WriteParList ? change-over of motor parameters in 2ms
Solved function restrictions:
Untrue running of power loss-optimised modulation modes (Eliminated from FW 12.00)
Function of the inversion of motor phase rotating direction only for V/f (Eliminated from FW 12.00)
Jerk during the deactivation of DC-injection braking at n_act ≠0 (Eliminated from FW 12.00)
Application of n_act ≠0 in SC-ASM control mode is not compensated (Eliminated from FW 12.00)
Brake chopper threshold, LU-threshold, and DC-voltage incorrect in the case of 230 V devices (Eliminated from FW 12.00)
Overcurrent during the transition from open-loop operation to closed-loop controlled operation SLPSM (Eliminated from FW 12.00)
Oscillation tendency in the case of a very dynamic setpoint change in SLVC (Eliminated from FW 12.00)
OC1 error after enable in the case of SM with a low inductance (Eliminated from FW 12.00)
Sporadic OC13 error during DC-injection braking (Eliminated from FW 12.00)
Flying restart process in SLVC after change-over of the control mode without function (Eliminated from FW 12.00)
Setpoint current in SLPSM cannot be preselected higher than 328 % (Eliminated from FW 12.00)
SU03 error in the case of DC supply (Eliminated from FW 12.00)
Fixed 3 ms PT1 filtering in the analog inputs 1+2 (Eliminated from FW 12.00)
Difference descriptions:
not existing
Version VE
Function extensions:
not existing
Solved function restrictions:
not existing
Function restrictions:
not existing
Difference descriptions:
not existing
This Version-History was created starting with version V12.00.00.0000.
URL for linking this AKB article:
https://www.lenze.com/en-de/go/akb/202300276/1/
Meta data
Taxonomy: 8400 HighLine frequency inverters
AKB-ID: 202300276
Last update: 2023/09/13
Category: Versions Histories
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.
©
Change location
Imprint
Privacy policy
Terms of use
Contact form