Overcurrent monitoring (overload monitoring) OC18

Function description:

The code 'Current monitoring: Delay time' (C563/1) can be used to select a delay time which after the set time and after exceeding the 'Current monitoring: Switch-off current' (C0124/0) will activate the error oC18.

The response of oC18 can be set via code C584/1.

For more information, please refer to the corresponding Software Manual.

Contained in which products?

Inverter Drives 8400 StateLine V16.00.00
Inverter Drives 8400 HighLine V16.00.00
Inverter Drives 8400 TopLine V16.00.00

Inverter Drives 8400 motec V07.00.00

Inverter Drives 8400 Protec HighLine V16.00.00

Inverter Drive 8400 Protec StateLine V08.00.00

Application:
Applications requiring a quick response to the sluggishness of a machine (e.g. of gearboxes) or load changes to prevent or reduce consequential damage.