Profinet station name cannot be written

Corrected from: 

  • Inverter Drives 8400 HighLine V14.00.00
  • Inverter Drives 8400 HighLine V14.00.00
  • Inverter Drives 8400 TopLine V14.00.00

and a Profinet module from FW version 02.06

Response of the new version:
The string codes C13899/1…8 for the station name can be written to as expected.

 


 

Which products are affected?

8400 StateLine, HighLine and TopLine: FW version ≤ 13.00.00.00 and a Profinet module with a FW version ≤ 02.01.
 
What happens?
The string codes C13899/1…8 for the station name cannot be written to.
 
When does the problem occur?
String codes of the Profinet module cannot be written to.
 
Diagnostics options?
This response can for example be observed when the parameters C13899/1…8 in the Engineer parameter list are changed online. 
 
Short-term measures/recommendations?
None.
 
Evaluation:
The Profinet module cannot be designated with a station name in the codes.  