Additional error messages of reaction type 'Information'
Function extension:
Additional error messages with 'Information' as possible reaction type were created. They are used for enhanced device diagnostics. The following messages have been added:
"Su07: 24V-supply OFF": Will be entered due to the drop of the 24V-supply voltage when the operating system is shut down
"dF01: FW updated": Will be entered when a software update is started (starting from this version, the retain data will be backed up as well during software updates).
"PS11: Lenze setting loaded": Will be entered when the Lenze settings are being loaded via C0002/1.
"PS12: Parameter sets loaded": Will be entered when the parameters are being loaded via C0002/6.
"PS13: Parameter sets saved": Will be entered when the parameters are being saved via C0002/11.
The reaction type of the messages can selected by setting code C0575/xx to "0: no reaction" or "6: Information".