Additional error messages of reaction type 'Information'

Function extension:

Additional error messages with 'Information' as possible reaction type were created. They are used for enhanced device diagnostics. The following messages have been added:

  • "Su07: 24V-supply OFF":
    Will be entered due to the drop of the 24V-supply voltage when the operating system is shut down
  • "dF01: FW updated":
    Will be entered when a software update is started (starting from this version, the retain data will be backed up as well during software updates).
  • "PS11: Lenze setting loaded":
    Will be entered when the Lenze settings are being loaded via C0002/1.
  • "PS12: Parameter sets loaded":
    Will be entered when the parameters are being loaded via C0002/6.
  • "PS13: Parameter sets saved":
    Will be entered when the parameters are being saved via C0002/11.

The reaction type of the messages can selected by setting code C0575/xx to "0: no reaction" or "6: Information".

Contained in which products?
Inverter Drives 8400 StateLine V16.00.00
Inverter Drives 8400 HighLine V16.00.00
Inverter Drives 8400 TopLine V16.00.00
 
Inverter Drives 8400 protec HighLine V16.00.00

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500428/1/