Sensitivity threshold for the transfer of the actual speed as setpoint

Which products are affected?
Inverter Drives 8400 HighLine and TopLine from firmware version 12.00.00.00


Functional description
When the 'StandBy' state is changed to a setpoint-controlling operating mode of the MCK (e.g. speed follower, positioner, …), the current speed is transferred as setpoint. This is required for the connection to a rotating drive. In C2611/5, a threshold can be defined up to which not the current speed is transferred, but a setpoint value of '0' is set.


Applications
Avoiding the transfer of very low speeds during the change to the 'Positioning' operating mode, which might cause a drift as long as a start of positioning is not requested.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201301010/1/