Which products are affected?
Inverter Drives 8400 HighLine and TopLine from firmware version 12.00.00.00
Functional description
Positions that are specified in application units [units] cannot be converted to increment positions as integers in correlation of the machine parameter feed constant and gearbox factor. Without further measures, the residual value of the conversion, e.g. 0.333 increments, would be lost. For the cyclically recurrent use of the position with an inherent residual value, e.g. in the form of a relative positioning, the current position would drift.
The effect of the function extension is that residual values are forwarded from FB to FB in the background.
Applications
Selection of target positions in application units for relative positioning processes.
Taxonomy:
8400 HighLine frequency inverters
,
8400 TopLine frequency inverters
AKB-ID:
201301078