Measurement of the distance between the home mark/limit switch and TP/MP
Which products are affected?
Inverter Drives 8400 HighLine and TopLine from firmware version 14.00.00.00
Functional description
For homing modes 4,5,6,7,10,11, the display code 1210/9 [units] has been added, in which the distance between the home mark and the TP signal can be read out after homing has been carried out. If these two homing signals are very close to each other, repeatability of the home position may not be given, depending on the jitter of the home mark.
The display of the distance between the home mark and the TP signal supports the user in deciding whether repeatability can be reliable or not.