Function extension:
Parameter 0x2C42:016 can be used to differentiate between rotary and linear feedback systems:
- 0x2C42:016= [0]: rotary
- 0x2C42:016= [1]: linear
For linear feedback systems, an extended settings dialog is nowavailable inthe engineering tool, making the parameterization of linear encoders more user-friendly.
Linear encoder-specificparameters (typical values from the data sheet)canbe entered directly via the"Calculation aid" dialog (Calculate button). These are then automatically converted to the values required for the internal rotary architecture of the i950.


Included in the following products:
Servo inverter i950 FW: from V01.14.00
Easy Starter: from V01.29.00
Application:
Parameterization of linear feedback systems (linear encoders) for linear motors or linear measuring systems.
[Automatic Translation]