i950: Synchronization function via digital input (digital IO) (from V01.14.00)

Function extension:
Application synchronization via digital input:
The application in the i950 can now also be synchronized with other devices via an external signal source and a digital input from the inverter.

Included in the following products:
Servo inverter i950 FW: from V01.14.00 

Application:
Synchronization of multiple converters via an external synchronization source using using the converters' digital inputs.

Related parameters:

0x2581:001 Application synchronization: Sync source: zAdditional selections for digital inputs:

  • 0x2581:001=[2]: Digital input 1
  • 0x2581:001=[3]: Digital input 2
  • 0x2581:001=[4]: Digital input 3
  • 0x2581:001=[5]: Digital input 4

0x2582:001..004 Application synchronization: Sync settings:
Settings for synchronization via digital input,analogous to the settings for synchronization via CANopen:

ID-202500402-Screenshot-0x2582.png


[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202500402/1/