Adjustable voltage reserve for field weakening operation - ASM
Function extension: Via the new C2871 'Voltage reserve' parameter, users can directly select the voltage reserve for operation in the field weakening range. With the Lenze setting, the voltage reserve will be 5%, as before.
Contained in which products?
9400 HighLine from firmware version 12.00.18.00
9400 Servo PLC from firmware version 06.00.18.00
Application:
Special asynchronous motors (as well as some Lenze IE2 motors) require a higher voltage reserve than the default setting of 5% for stable d-current control. This only applies to servo control - ASM (C6=2).
Taxonomy:
9400 HighLine servo inverters
,
9400 Servo PLC servo inverters
AKB-ID:
201500336
Last update:
2023/09/09
Category: