Area stampa
Comunicati stampa
Attualità
Blog
Fiere ed eventi
Newsletter
Carriera
Offerte di lavoro
Offerte di lavoro per professionisti con esperienza
Download
App di engineering
Dati di engineering
Tool di engineering
Application Knowledge Base - articoli AKB sui prodotti
Documentazione sui prodotti
Certificati e dichiarazioni di conformità
Online Tools
EASY Product Finder
Dimensionamento
Progettazione
CAD Configurator
Curve caratteristiche M-n
Smart Conveyor Calculator
Contatti
Lenze in Italia
Lenze nel mondo
Modulo di contatto
Italia (Italy)
Italiano
English
Change country
Prodotti
IIoT
Controlli
Inverter
Motoriduttori
Motori
Riduttori
Accessori
Software
Lenze FAST Application Software
Lenze Selection
Soluzioni
Sistemi
Il nostro hardware
X4 Remote
Motion Control
L’IT incontra l’OT
Automazione
Tecnologia di sicurezza
Il nostro hardware
Il nostro software
OEE & downtime tracking
Visualizzazione di macchina
Engineering Suite
app di SMART engineering
Il nostro software
Il nostro brainware
Digital Solutions
Condition Monitoring
Digital Twin
Servizio di engineering Lenze
Performance Partner Lenze
Il nostro brainware
Sistemi
Meccatronica
Mechatronic Competence Campus
Decentralized Drive Packages
Energy efficiency
Smart Conveyor Story
Meccatronica
Etichettatura del marchio
Settori industriali
Settore automobilistico
Referenze
Settore automobilistico
Produzione di batterie
Macchine da stampa e converting.
Referenze
Macchine da stampa e converting.
Azionamenti per Autolavaggi
Logistica aeroportuale
Vetro, pietra e ceramica
Lavorazione del legno
Azionamenti per applicazioni HVAC-R
Sistemi di refrigerazione e pompe di calore
Ventilation equipment
Azionamenti per applicazioni HVAC-R
Industria della plastica
Courier Express Parcel
Logistica di magazzino
Solutions Storage and retrieval machine
Logistica di magazzino
Lavorazione dei metalli
Pumps
Robotics
settore tessile
Referenze
settore tessile
Settore confezionamento e imballaggio
Referenze
Settore confezionamento e imballaggio
Settori industriali
References
Converting and printing industry
BST
Donghang Graphic Technology Inc.
DURST Group
D.W. Engineers
GIC
MAAN Engineering
Mendel RG Systems
Nikelman Printing press
Relinquo Automation Pvt. Ltd.
Suddha Machineries and Industries PVT LTD
Converting and printing industry
Airport logistics
Courier, Express & Parcel
Warehouse logistics
bonArea
Stöcklin High-bay warehouse
Vectron
Witron Warehouse logistics
Warehouse logistics
Textile industry
Dilmenler
Gilbos
MBK and DMS Dilmenler
Menzel Compact washer
Monforts Textile machine
nomaco nonwoven machines
nsc.n schlumberger
Macchine tessili da Picanol
Pro-SMH
Texpro
Trigema and Xetma Vollenweider
Zimmer Austria
Textile industry
Packaging industry
Citus Kalix Packaging machine
DMK
Fricke Abfülltechnik
Kletec Egg processing machines
MAKRO MAKINA
Mondini
PAYPER
TechNikkels
Wolf Packaging machines
XOX Retrofit Extruder
Packaging industry
Further industries
Bauer
HEGLA New Technology
KABTEC Test systems
Lisec
MFL
Schelling Sawing center
Weinig Grecon
Further industries
References
Soluzioni
Service
Servizio post-vendita
Training
On-site training
E-Learning
Training online
Training
Servizio di engineering
Cyber Security
Cyber Security Statements
Cyber Security
Download software
EASY Engineering Tools
App di engineering
Dati di engineering
Download software
Knowledge Base
Application Knowledge Base
Documentazione sui prodotti
Documentazione sull’azienda
Knowledge Base
Product-Lifecycle-Management
X4 Remote Support
Service
Supporto
Azienda
Il Gruppo
Il nostro obiettivo
Il nostro impegno per la Qualità
Industry 4.0
Il nostro obiettivo
La nostra responsabilità
Responsabilità per i dipendenti
Impegno nel sociale
La nostra responsabilità
La nostra cultura aziendale
Il management
La nostra storia
History Lenze
100 Anni di Elisabeth Belling
La nostra storia
Il Gruppo
Presenza globale
Africa
Lenze in Sudafrica
Africa
America
Lenze in Brasile
Lenze in Canada
Lenze in Messico
Lenze negli USA
America
Asia
Lenze in Cina
Lenze in India
Lenze in Corea
Lenze nelle Filippine
Lenze a Singapore
Lenze in Turchia
Asia
Nord Europa
Lenze in Danimarca
Lenze in Finlandia
Lenze in Svezia
Nord Europa
Europa occidentale e centrale
Lenze in Belgio
Lenze in Germania
Lenze in Estonia
Lenze in Francia
Lenze in Lettonia
Lenze in Lituania
Lenze in Austria
Lenze nei Paesi Bassi
Lenze in Polonia
Lenze in Svizzera
Lenze nel Regno Unito
Europa occidentale e centrale
Europa orientale
Lenze in Bulgaria
Lenze in Macedonia
Lenze in Romania
Lenze in Russia
Lenze in Serbia
Lenze in Slovacchia
Lenze in Slovenia
Lene nella Repubblica Ceca
Lenze in Ungheria
Europa orientale
Sud Europa
Lenze in Italia
Lenze in Croazia
Lenze in Macedonia
Lenze in Spagna
Sud Europa
Presenza globale
Sostenibilità
Direttiva RAEE
Sostenibilità
Conformità
Area stampa
Comunicati stampa Gruppo Lenze
Attualità
Blog
Fiere ed eventi
Newsletter
Area stampa
Carriera
Offerte di lavoro
Offerte di lavoro Germania
Current vacancies in Poland
Current vacancies Benelux and UK
Current vacancies Switzerland
Current vacancies USA
Current vacancies China
Offerte di lavoro
Noi siamo Lenze
Offerte di lavoro per professionisti con esperienza
Carriera
Global Procurement
Azienda
Italia (Italy)
Italiano
English
Change country
Home
Application Knowledge Base
Articolo
Versions-History Controller p300
Versions-History Controller p300
Version V03.21.03.0000
Function extensions:
not existing
Solved function restrictions:
EtherCAT master is not automatically updated with the controller
After a device exchange of an EtherCAT slave, the EtherCAT is not operational. (corrected from V3.21.3 / V1.9)
Function restrictions:
Error message "No access-parameter set was not saved"
User parameter of data type SINT cannot be changed with EASY Starter
OPC UA connection is terminated when displaying structures with substructures
Boot application with encrypted application not possible (no correction planned)
Task configuration - Monitoring: Element jitter does not show instantaneous value
Controller reports bus configuration error after firmware update of an i950
Task configuration: Display of a too large jitter value
MMC: Bits "IsPresent" and "IsMandatory" at c250-S without function
No access to a "REFERENCE TO" variable
PLC Designer : FAST Motion visualization elements can no longer be assigned to a frame
Error messages when connecting with OPC UA Expert
IP address is not taken over after firmware update (restore)
Error message when loading or downloading a device application
p300 / c300: OPC UA error messages when starting without Ethernet
Watchdog exception when using functions from the SysTimeRTC library
Exception after online change
Trace file is not saved safe against mains failure
Controller does not start after executing a restore
PROFINET I/O device: IP address and station name are not displayed correctly
Parameter sets of the devices connected to the controller are not stored power safe
EtherCAT master changes to 'operational' although firmware version of slave is too low
Message when logging in that the device version in the project is older than the device
Premature switch-off of c300/p300 controller after update or restore leads to data loss
Controller's WebConfig cannot be reached
L_ETC_GetMasterDiagnostic: Value of xNotAllSlavesOperational bit is not correct
EtherCAT slaves cannot be accessed using EASY Starter/Engineer
With 'Reload boot project' (WebConfig), the persistent variables are reset
Process data is not transmitted in every PLC cycle
In the case of large files, file transfer is aborted
p300: VisiWinNET cannot establish connection to PLC
Jitter of up to 1ms in task with the highest priority
Communication between controller and PLC Designer is aborted when downloading a project
Cycle time extension in the task with the highest priority due to the use of network variables
Version V03.21.02.0000
Function extensions:
not existing
Solved function restrictions:
Safety modules: Data type of the instantiated function module has changed (corrected from controller device description V01.08 / V03.21.02)
CAA DTUtility: FB 'SetDateAndTime' reports "DTU_ERROR_UNKNOWN" (corrected from V3.21.2)
L_ETC_ReadErrCnt2: EtherCAT fault is not displayed (corrected from V3.26)
Some time zones are not adjustable (C92) (corrected from V3.21.2)
Version V03.21.00.0000
Function extensions:
Object 'ParameterEditor'
Solved function restrictions:
IO-1000: Error messages when translating the PLC project
No compiler error when using retain variables > 128kB (corrected from V3.21)
Error message 'Evaluation of backup job failed' (corrected from V3.21)
Persistent variables have initial value after interruption of project download (corrected from V3.21)
Version V03.20.01.0000
Function extensions:
not existing
Solved function restrictions:
OPC/UA server returns wrong endpoint URL (fixed as of V3.20.1)
Error message 'Error writing parameter 0x500A:054' during parameter set download (fixed as of V3.20.1)
Controller does not start automatically after performing an update/restore (fixed as of V3.20.1)
Version V03.20.00.0000
Function extensions:
Parameter C0640: New option for automatic firmware update of EtherCAT slaves (from V03.20.00)
OPC-UA: Changed data type when accessing TIME variables
Solved function restrictions:
Watchdog exception after device exchange when starting the boot project (corrected for projects created for controllers from V3.21.2)
Fields on parameter dialogues do not change colour online and do not show correct values (fixed from V1.5, V3.20)
OPC UA communication stops (corrected from V3.20)
EtherCAT bus becomes operational, although parameters could not be written during the initialization phase (corrected)
OPC/UA access to structures does not work (corrected from V3.20)
Version V03.19.00.0000
Function extensions:
not existing
Solved function restrictions:
p300: Code 424 (Auto dimming: time) displays no values (corrected from V3.19)
Version V03.18.01.0000
Function extensions:
not existing
Solved function restrictions:
not existing
Version V03.18.00.0000
Function extensions:
i550: Parameter set download if required
Solved function restrictions:
Login to safety control c250s not possible (fixed from V3.18)
EtherCAT does not start after updating the boot project and restarting the controller (fixed from V3.18)
Digital outputs are not set to '0' after exception (fixed from V3.18)
EtherCAT does not change to 'Operational' (fixed from V3.18)
Version V03.17.01.0000
Function extensions:
Support of the current Lenze libraries
Solved function restrictions:
Extended start-up time of p300 panel controller (WEC7 Professional operating system) (eliminated from V3.17.1)
Version V03.17.00.0000
Function extensions:
L_IODrvEtherCAT: Reading out the 'Second Station Address' of an EtherCAT slave
Solved function restrictions:
not existing
Version V03.16.00.0000
Function extensions:
Enhanced LED signalling for backups, restores and updates
New VNC server
Controller supports firmware download to i550 frequency inverter
Solved function restrictions:
Configured EtherCAT slave bridge leads to log off after project downloads (corrected from V3.16)
Controller does not start (corrected from V3.16)
Despite TRY/CATCH instruction, PLC processing stops if an exception occurs (corrected from V3.16)
Version V03.15.01.0000
Function extensions:
not existing
Solved function restrictions:
Defective SD cards when using device descriptions
Version V03.15.00.0000
Function extensions:
Support of Safety Controller c250-S
Solved function restrictions:
EtherCAT DC synchronisation gets lost (corrected from V3.15)
Version V03.14.00.0000
Function extensions:
Controller supports parameter set download in i550
L_MC1P_BasicActuatingSpeed: p300 supports axis operation in the speed-controlled Velocity mode (vl) (from V3.14.0)
Solved function restrictions:
L_ETC_CoE_SdoWriteEx with CompleteAccess no longer returns an error code when writing to ReadOnly parameters (corrected from V3.14)
SD card label is not placed correctly (corrected from CW8/2017)
Regional and language options (C93) are not saved fail-safe (corrected from V3.14)
RETAIN variables are reset after restarting the controller (corrected from V3.14)
Exception "AccessViolation" in the case of invalid name of recipe definition (corrected from V3.14)
Version V03.13.01.0000
Function extensions:
Support of PROFINET device as optional fieldbus
Solved function restrictions:
p300 starts with a dark screen (corrected from V3.13.1)
Version V03.13.00.0000
Function extensions:
Version check by Backup&Restore
Solved function restrictions:
Controller indicates incorrect time after restart (corrected from V3.13)
L_ETC_MMCControllerBus: No Ethernet connection to controller after cancellation of the "ADDR_ASSIGMENT_EXTERNALLY" service (corrected from V3.13)
Version V03.12.00.0000
Function extensions:
L_DMParameterAccess: Saving parameters safe against mains failure
Saving the I/O 1000 parameter set to the boot project of the controller
New product variant with enhanced functionality for p300 panel controller
EASY Starter supports c300 and p300
Support of Ethernet-based functions
EtherCAT fieldbus is supported as master
Support of modular machine configuration for EtherCAT
Solved function restrictions:
Task overflow when using CAN (corrected from V3.12)
"CAA Net Base Services" library is not supported (corrected from V3.12)
Longer cycle times due to FTP access or Telnet connection (corrected from V3.12)
Increased cycle time in the task with the highest priority due to the use of the CAA_File library (corrected from V3.12)
Version V03.10.00.0000
Function extensions:
not existing
Solved function restrictions:
No screen output when executing a batch file (corrected from V3.10)
Version V03.09.01.0000
Function extensions:
not existing
Solved function restrictions:
Sporadically, controller does not boot (corrected from V3.9.1)
Version V03.09.00.0000
Function extensions:
p300 controller with 1000 power tags
p300 display rotation
Solved function restrictions:
L_DMParameterAccess function block outputs 28 via dwErrorID (corrected from V3.9)
No communication via CAN on Visu devices after exiting and restarting all applications (corrected from V3.9)
Watchdog is not triggered (corrected from V03.09)
Error message when preparing a USB stick for a restore (corrected from V3.9)
Version KW46/2016
Function extensions:
not existing
Solved function restrictions:
not existing
Function restrictions:
not existing
Version 02/2015
Function extensions:
not existing
Solved function restrictions:
not existing
Function restrictions:
not existing
URL for linking this AKB article:
https://www.lenze.com/en-de/go/akb/202300292/1/
Meta data
Taxonomy: Controller p300
AKB-ID: 202300292
Last update: 2023/09/13
Category: Cronologia versioni
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.
©
Modifica sede
Colophon
Protezione dei dati
Condizioni di utilizzo
Modulo di contatto