Sala de redacción
Notas de prensa
Novedades
Blog
Ferias y eventos
Boletín de noticias
Ofertas de trabajo
Ofertas de empleo
Ofertas para profesionales con experiencia
Descargas
Aplicaciones de ingeniería
Datos de ingeniería
Herramientas de ingeniería
Artículos de productos de la Application Knowledge Base
Documentación del producto
Certificados y declaraciones
Online Tools
EASY Product Finder
Dimensionar el accionamiento
Diseñar la máquina
CAD Configurator
Características M-n
Smart Conveyor Calculator
Contacto
Lenze en España
Lenze en todo el mundo
Formulario de contacto
España (Spain)
Español
English
Change country
Productos
IIoT
Controladores
Convertidores
Motorreductores
Motores
Reductores
Accesorios
Software
Lenze FAST Application Software
Lenze Selection
Soluciones
Sistemas
Nuestro hardware
X4 Remote
Motion Control
IT meets OT
Automatización
Funciones de seguridad
Nuestro hardware
Nuestro software
NUPANO Open Automation Platform
OEE & Downtime Tracking
Machine Visualization
Engineering Suite
SMART Engineering Apps
Nuestro software
Nuestro brainware
Digital Solutions
Condition Monitoring
Gemelo Digital
Servicio de ingeniería de Lenze
Lenze Performance Partners
Nuestro brainware
Sistemas
Mecatrónica
Mechatronic Competence Campus
Decentralized Drive Packages
Energy efficiency
Smart Conveyor Story
Mecatrónica
Etiquetado de marcas
Sectores
Industria del automóvil
Referencias
Industria del automóvil
Producción de baterías
Industria del converting y las artes gráficas
Referencias
Industria del converting y las artes gráficas
Unidades de lavado de vehículos
Logística aeroportuaria
Vidrio, piedra y cerámica
Mecanizado de la madera
HVAC-R
Tecnología de refrigeración y bombas de calor
Ventilation equipment
HVAC-R
Industria del plástico
Courier Express Parcel
Logística de almacenes
Soluciones para transelevadores
Logística de almacenes
Mecanizado de metales
Pumps
Robotics
Industria textil
Referencias
Industria textil
Industria del embalaje
Referencias
Industria del embalaje
Sectores
References
Converting and printing industry
BST
Donghang Graphic Technology Inc.
DURST Group
D.W. Engineers
GIC
MAAN Engineering
Mendel RG Systems
Nikelman Printing press
Relinquo Automation Pvt. Ltd.
Suddha Machineries and Industries PVT LTD
Converting and printing industry
Airport logistics
Courier, Express & Parcel
Warehouse logistics
bonArea
Stöcklin High-bay warehouse
Vectron
Witron Warehouse logistics
Warehouse logistics
Textile industry
Dilmenler
Gilbos
MBK and DMS Dilmenler
Menzel Compact washer
Monforts Textile machine
Nomaco Nonwoven machines
nsc.n schlumberger
Picanol Weaving machines
Pro-SMH
Texpro
Trigema and Xetma Vollenweider
Zimmer Austria
Textile industry
Packaging industry
Citus Kalix Packaging machine
DMK
Fricke Abfülltechnik
Kletec Egg processing machines
MAKRO MAKINA
Mondini
PAYPER
TechNikkels
Wolf Packaging machines
XOX Retrofit extruder
Packaging industry
Further industries
Bauer
HEGLA New Technology
KABTEC Test systems
Lisec
MFL
Schelling Sawing center
Weinig Grecon
Further industries
References
Soluciones
Servicio técnico
Servicio posventa
Formación
Formación presencial
Aprendizaje online
Formación online
Formación
Servicio de ingeniería
Cyber Security
Cyber Security Statements
Cyber Security
Descargas de software
EASY Engineering Tools
Engineering Apps
Datos de ingeniería
Descargas de software
Knowledge Base
Application Knowledge Base
Documentación del producto
Documentación de la empresa
Knowledge Base
Product-Lifecycle-Management
X4 Remote Support
Servicio técnico
Asistencia
Empresa
Grupo empresarial
Nuestro enfoque
Compromiso de calidad
Industria 4.0
Nuestro enfoque
Nuestra responsabilidad
Responsabilidad por los empleados
Compromiso social
Nuestra responsabilidad
Nuestra cultura empresarial
Nuestra dirección
Nuestra historia
History Lenze
100 years Elisabeth Belling
Nuestra historia
Grupo empresarial
Presencia global
África
Lenze en Sudáfrica
África
América
Lenze en Brasil
Lenze in Canada
Lenze en México
Lenze en EE. UU.
América
Asia
Lenze en China
Lenze en la India
Lenze en Corea
Lenze en Filipinas
Lenze en Singapur
Lenze en Turquía
Asia
Europa del Norte
Lenze Dinamarca
Lenze en Finlandia
Lenze en Suecia
Europa del Norte
Europa Occidental y Central
Lenze en Bélgica
Lenze en Alemania
Lenze en Estonia
Lenze en Francia
Lenze en Letonia
Lenze en Lituania
Lenze in Austria
Lenze en los Países Bajos
Lenze en Polonia
Lenze en Suiza
Lenze en el Reino Unido
Europa Occidental y Central
Europa del Este
Lenze en Bulgaria
Lenze in Macedonia
Lenze en Rumanía
Lenze en Rusia
Lenze in Serbia
Lenze en Eslovaquia
Lenze en Eslovenia
Lenze en la República Checa
Lenze en Hungría
Europa del Este
Europa del Sur
Lenze en Italia
Lenze en Croacia
Lenze en Macedonia
Lenze en España
Europa del Sur
Presencia global
Sustainability
Directiva RAEE
Sustainability
Cumplimiento
Sala de redacción
Notas de prensa del Grupo Lenze
Novedades
Blog
Ferias y eventos
Boletín informativo
Sala de redacción
Ofertas de trabajo
Ofertas de empleo
Vacantes Alemania
Current vacancies in Poland
Current vacancies Benelux and UK
Current vacancies Switzerland
Current vacancies USA
Current vacancies China
Ofertas de empleo
Somos Lenze
Ofertas para profesionales con experiencia
Ofertas de trabajo
Global Procurement
Empresa
España (Spain)
Español
English
Change country
Home
Application Knowledge Base
Artículo
- Version history - 8400 HighLine Software (SW) ≤ V010.xx
- Version history - 8400 HighLine Software (SW) ≤ V010.xx
Mit Engineer 2.13 und 2.14:
Function restrictions:
-
Parameter change-over - Error when editing the list of change-over parameters by means of Engineer 2.13 and 2.14
8400 HighLine Software (SW) V10.xx:
(Gerät mit neuem Hardware-Stand erforderlich)
Function extensions:
-
(from V10.00 onwards)
-
QSP with position control
(from V10.00 onwards)
-
QSP in the case of torque control with speed limitation
(from V10.00 onwards)
-
Motor control type 'sensorless control of synchronous machine (SLPSM)'
(from V10.00 onwards)
-
'VFCplusEco' motor control type
(from V10.00 onwards)
-
Display of the actual speed value at switched off mains voltage
(from V10.00 onwards)
-
Ultimate motor current, C0939
(from V10.00 onwards0)
-
Setting of the magnetisation
(from V10.00 onwards)
-
Magnetisation time reduced
(from V10.00 onwards)
Eliminated function restrictions:
-
(eliminated from V10.00)
Function restrictions:
-
8400 HighLine Software (SW) V06.xx:
Function extensions:
-
(from V06.00 onwards)
Eliminated function restrictions:
-
(from V06.00 onwards)
Function restrictions:
-
8400 HighLine Software (SW) V05.xx:
Function extensions:
-
(from V05.01 onwards)
Eliminated function restrictions:
-
(from V05.01 onwards)
Function restrictions:
-
8400 HighLine Software (SW) V04.xx:
Function extensions:
Analog input 1 - Minimum speed (L-C00010) (from V4.0 onwards)
Boost input at function block LS_MotorInterface (from V4.0 onwards)
Function blocks - Configurable behaviour of the blocks LS_AnalogOutput, LS_DigitalOutput, LP_CanIn and LP_CanOut in the event of a fault/error (from V4.0 onwards)
Integration of a safety control word for setpoint generation Safe Stop (SS1) (from V4.0 onwards)
Configurable group error signal at the LS_DriveInterface system block (from V4.0 onwards)
Motor brake for braking without brake resistor (from V4.0 onwards)
New application 'Shutdown positioning' (C00005 = 3000) (from V4.0 onwards))
New function blocks (from V4.0 onwards)
Table positioning - Deactivation of the position encoder during certain position control modes (from V4.0 onwards)
Table positioning - Override for acceleration, deceleration and S-ramp time (from V4.0 onwards)
Table positioning - Positioning stipulation in 'units' (16 bit / 32 bit) (from V4.0 onwards)
Reversal of motor phase sequence for correction of cable errors (from V4.0 onwards)
V/f characteristic control with 11 interpolation points that can be set (from V4.0 onwards)
Eliminated function restrictions:
Indication for brake resistor utilisation for the 400 V devices incorrect (remedied from V4.0 onwards)
Output signals of the motor controller are not updated if overvoltage occurs (remedied from V4.0 onwards)
Sensorless Vector Control (SLVC) operating mode - Motor does not start (remedied from V4.0 onwards)
Servo control (SC) operating mode - Application to a motor that is rotating fast only works to a limited extent in the case of torque limitation (remedied from V4.0 onwards)
Operating mode V/f characteristic with retraction (VFCplus) - The Imax limit can be exceeded if there is a mechanical blockade (nact= 0 rpm) (remedied from V4.0 onwards)
CANopen - Sending sequence of Emergency and BootUp telegrams when device is switched on (remedied from V4.0 onwards)
Ixt monitoring at switching frequency of 16 kHz faulty (remedied from V4.0 onwards)
If an error message is active, the motor starts after the factory adjustment has been loaded (remedied from V4.0 onwards)
Encoder evaluation faulty when motor parameters have been modified (remedied from V4.0 onwards)
Table positioning - Torque surge during reference run (remedied from V4.0 onwards)
Table positioning - No harmonic setpoint adopted when the operating mode is changed (remedied from V4.0 onwards)
Table positioning - Control bits are blocked if the specified profile is incorrect (remedied from V4.0 onwards)
Function extenstions:
Additional setpoints nAuxSetValue_a - Drive connects with a too high setpoint
8400 HighLine Software (SW) V02.xx:
Function extensions:
Adapting the deceleration ramp when the DC-bus voltage is too high (from SL:V3.0 HL:V2.0 onwards)
Vector control (SLVC) operating mode - Forward control of the speed setpoint (from SL:V3.0 HL:V2.0 onwards)
Vector control (SLVC) operating mode - adjustable magnetising time (from SL:V3.0 HL:V2.0 onwards)
CANopen - Setting the PDO data length (from SL:V3.0 HL:V2.0 onwards)
CANopen - 'HeartBeat Consumer' protocol function available (from SL:V3.0 HL:V2.0 onwards)
CANopen - static PDO mapping and CAN-In simulation (from SL:V3.0 HL:V2.0 onwards)
Extension of the encoder evaluation (from SL:V3.0 HL:V2.0 onwards)
EtherCAT - Support of the communication module (from SL:V3.0 HL:V2.0 onwards)
Safe Torque Off (STO) function (from SL:V3.0 HL:V2.0 onwards)
L_ArithmetikPhi function block - Arithmetic extended by multiplication and division (from V2.0 onwards)
Mains phase failure detection (from SL:V3.0 HL:V2.0 onwards)
Process controller - additional output signals and operating modes (from SL:V3.0 HL:V2.0 onwards)
Brake resistor monitoring - I²xt monitoring (from SL:V3.0 HL:V2.0 onwards)
Support of device powers up to and including 15 kW (from SL:V3.0 HL:V2.0 onwards)
Eliminated function restrictions:
Analog input - Setpoint selection via master current value not possible with open-circuit monitoring (remedied from SL:V3.0 HL:V2.0 onwards)
Faulty display of the brake resistor utilisation (remedied from SL:V2.01 / HL:V3.01 onwards)
Automatic DC-injection brake - delayed start of the motor when the Sensorless Vector Control (SLVC) or Servo control (SC) operating mode is selected (remedied from SL:V3.0 HL:V2.0 onwards)
Limitation of the field frequency causes the drive to vibrate (remedied from SL:V3.0 HL:V2.0 onwards)
Servo control operating mode - Default setting deactivates the field weakening controller (remedied from V2.0 onwards)
Control mode V/f characteristic (VFCplus) - Imax error (OC10) when starting after mains connection (remedied from SL:V3.0 HL:V2.0 onwards)
CAN bus - Device does not respond to the reception of NMT telegrams (remedied from SL:V3.0 HL:V2.0 onwards)
Function block L_GainOffsetPhi and L_OffsetGainPhi - Faulty calculation (remedied from V2.0 onwards)
Function block L_SampleHold does not save the value in case of power off (remedied from V2.0 onwards)
ID1 error during motor identification (remedied from SL:V2.01 / HL:V3.01 onwards)
No LU message after switching on the control voltage (24 V) (remedied from SL:V3.0 HL:V2.0 onwards)
Logbook - sporadically wrong display of the error counter (remedied from V2.0 onwards)
Restricted motor phase failure detection in the field weakening range (remedied from SL:V3.0 HL:V2.0 onwards)
Jerk when connecting to a rotating motor or after overvoltage (remedied from SL:V3.0 HL:V2.0 onwards)
Table positioning - Faulty torque limit during homing (remedied from V2.0 onwards)
(behoben ab V02.00)
Table positioning - Limitation of the automatic brake operation when the positioning operation is used (remedied from V2.0 onwards)
Table positioning - Hardware limit switch monitoring deactivated (remedied from V2.0 onwards)
Table positioning - Actual position is not updated in case of mains off (remedied from V2.01 onwards)
Table positioning - missing or faulty error message when using the software limit position monitoring (remedied from V2.0 onwards)
Table positioning - Profile data display does not indicate the new target position after Teach position (remedied from V2.0 onwards)
Table positioning - Rounding error when displaying the actual value (remedied from V2.0 onwards)
Counter for mains switching cycles faulty (remedied from SL:V3.0 HL:V2.0 onwards)
8400 HighLine Software (SW) V01.xx:
Function extensions:
Eliminated function restrictions:
Version history
(Intranet supplement)
, aspects which have only been publishe Lenze internal
URL for linking this AKB article:
https://www.lenze.com/en-de/go/akb/201001628/1/
Meta data
Taxonomy: 8400 HighLine frequency inverters
AKB-ID: 201001628
Last update: 2023/09/14
Category: Version Informations
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.
©
Cambiar la ubicación
Aviso legal
Protección de datos
Condiciones de uso
Formulario de contacto