CANopen - ¨HeartBeat Consumer¨ protocol function available (from SL:V3.0 HL:V2.0 onwards)
Function extension:
The 'HeartBeat Consumer' protocol function enables an 8400 StateLine frequency inverter to monitor up to 7 and an 8400 HighLine frequency inverter to monitor up to 15 further devices via CAN bus by means of the 'HeartBeat' telegram. If a 'HeartBeat' telegram of one or several nodes is missing the monitoring frequency inverter responds with the error response selected (L-C00592/5).
Applications
Monitoring the CAN communication between several frequency inverters or one control
In which products/versions is it included?
8400 StateLine SW V3.00 onwards
8400 HighLine SW V2.00 onwards
Taxonomy:
8400 HighLine frequency inverters
,
8400 StateLine frequency inverters
AKB-ID:
200902737
Last update:
2023/09/09
Category:
Version Informations