If an error message is active, the motor starts after the factory adjustment has been loaded (remedied from V4.0 onwards)

Remedied from:
8400 StateLine  SW V4.00 onwards
8400 HighLine   SW V4.00 onwards

Behaviour of the new version?
If the frequency inverter had been enabled (terminal RFR = HIGH) and was in the 'Fault' state, and the factory adjustment was loaded in this state, the fault was reset due to loading of the factory adjustment with the result that the motor immediately started again.
The above-named firmware version rectifies this functional restriction.




Which products are affected?
8400 StateLine  SW ≤ V3.01
8400 HighLine   SW ≤ V2.01

What happens?

...

Published with service message No. 2009/35