Corrected from:
Library: L_MC2P_MotionControlCam (FAST Motion) from V03.29.00
Response of the new version:
The slave axis now disengages at the desired position, even if the master clock in the modulo dimension system has been exceeded once.
What happens?
In case of different dimension system of master and slave, the slave axis does not disengage because the disengagement position cannot be reached due to the principle.
Background:
The disengaging position always refers to the position of the master axis (Y-axis).
If, for example, the movement is started in one direction and the master cycle in the modulo measuring system is exceeded once, the direct coupling to the slave is lost.
When does the behaviour occur?
- Master in the Modulo dimensional system and
- Slave in the Limited dimensional system.
Which products are affected?
Library: L_MC2P_MotionControlCam (FAST Motion)
Short-term measures / evaluation / recommendations:
The slave axis can be moved to the desired park position with an FB MC_MoveX.
Automatic Translation