Corrected from:
Library L_TW2P_TechModulesWindingTraversing (from V03.29.0)
(Update via Easy Package Manager)
Response of the new version:
The landing calculator calculates the valid target position MP_lrTargetMaterialCounterStopLine for the deceleration phase.
What happens?
The landing computer at the measuring point MP_lrTargetMaterialCounterStopLine drifts during the line's ramping phase.
When does the behaviour occur?
The Winder technology module is operated in winding mode. The line is stopped with the profile parameters lrSyncLineDec and lrLineJerk.
Which products are affected?
Function module L_TW2P_WinderDancerCtrl and L_TW2P_WinderTensionCtrl from library L_TW2P_TechModulesWindingTraversing (V03.26.0)
Short-term measures / evaluation / recommendations:
Basically, the landing calculator function is used together with the VelocityMaster mode. The calculation of the landing calculator in this mode is valid. If the winder is switched to the winding mode, the current counter reading of the material length counter should be used.
Automatic Translation