Corrected from:
Library: L_TS2PTechModulesSynchronizingCamming (from V03.26.00)
(Update via EASY Package Manager)
Response of the new
version:
Coupling with coupling mode eSyncMode = DistRelative can now also be done with consideration of eAllowDirection = Positive and a noisy conductance.
What happens?
When engaging, there is a jump in the profile (position) of the axle.
When does the behaviour occur?
The coupling mode eSyncMode = DistRelative is used. Here, only the positive direction of rotation is enabled for coupling: eAllowDirection = Positive.
The engagement is instructed with xSyncPos = TRUE.
In addition, the conductance (master position) is noisy.
Which products are affected?
L_TS2P_SyncAndCorrectionBase from library L_TS2PTechMoulesSynchronizingCamming
Short-term measures:
Switch to the coupling mode eSyncMode = 0 (ProfGenAbsolute).
Evaluation / recommendations:
Considering the short-term measure, under the given conditions, it is possible to couple like a noisy conductance with the mode eSyncMode = 0 (ProfGenAbsolute).