Hiperface DSL (OCT): When switching off, an encoder error is erroneously detected and the reference status is deleted (corrected from V01.05.02)
Corrected from:
Servo Inverter i950 FW: from V01.05.02.1788
Response of the new version:
When switching off the 24V supply, an encoder error is no longer erroneously detected and the reference status is no longer lost.
What happens?
As a result of the erroneous occurrence of an encoder error, the reference status reference-known is lost. After the next power-on, the reference position must be determined again.
When does the behaviour occur?
When using a Hiperface DSL feedback system in One Cable Technology (OCT) and when the 24V power supply is switched off. The slope of the ramp with which the 24V voltage drops has an influence on the probability of the encoder error occurring.