L_MC1P_PolePositionIdentification - identifying the pole position of synchronous motors (from V03.20.00)
Function extension: With the function block 'L_MC1P_PolePositionIdentification' the CiA operation mode 0x6060 = -12 can be used, which is implemented in the i950 from V01.04.01:
CiA Operation mode 0x6060 = -12 : Pole position identification
Contained in which products? Library: L_MC1P_MotionControlBasic from V03.20.00.102
Application: The Pollage Identification is used for the commissioning of 3rd-party synchronous motors. The block is the interface for the Lenze application software in the motion controller or the Soft PLC program in the i950 itself. Without this interface the mode is practically unusable.