Pole position identification PPI-360°: Triggering of monitoring for motor overtemperature or load

Corrected from:
Servo inverter i950 FW:  from V01.05.02.1788
 
Response of the new version:
The default for the current amplitude of the pole position identification 360° (PPI-360°) has now been reduced to 0x2C61:1 = 71 %.
Overheating of smaller motor types is thus now avoided.
 
 
What happens?
Pole position identification 360° (PPI-360°):
Smaller motor types can be subjected to high thermal loads, possibly to the extent that monitoring systems respond: Motor overtemperature or motor load (I²xt).
 
When does the behaviour occur?
Design of the PPI-360° for smaller motor types, e.g.: MCS06C41 and
parameterization of the current amplitude in default setting (0x2C61:1 = 100 %). 
 
Which products are affected?
Servo inverter i950 FW
 
Short-term measures / Evaluation/ Recommendations:
Reduction of the current amplitude for pole position identification 360° (PPI-360°) to 0x2C61:1 = 71%.

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202000079/1/