L_CM1P: Bitcoding Safety Status wrong (corrected from V03.20.00)

Corrected from:
Library:  (FAST Motion Modules V2) L_CM1P_ControlModules:   from V03.20.00.22
 
Response of the new version:
The bitcoding texts are correct and uniform across all TOs.

Bit 0 = STOActive
Bit 1 = SS1 Active
Bit 2 = SS1 Active
Bit 4 = SLS 1 Active
Bit 5 = SLS 2 Active
Bit 6 = SLS 3 Active
Bit 7 = SLS 4 Active
Bit 8 = SDIpos Active
Bit 9 = SDIneg Active 
 
What happens?
Texts of the bitcodings are partly wrong: 
 
Bit 0 = STOActive
Bit 1 = SS1 Active
Bit 2 = SS1 Active
Bit 3 = SLS 1 Active
Bit 4 = SLS 2 Active
Bit 5 = SLS 3 Active
Bit 6 = SLS 4 Active
Bit 7 = SDIpos Active
Bit 8 = SDIneg Active
 
When does the behaviour occur?
Using i950 servo inverter with TA Electronic Gearbox [40], TA Sync And correction [41], TA Winder Dancer-controlled [50], TA Winder Tension-controlled [51].
The bit coding texts of parameters 0x5040:111 /0x5050:111 are displayed in the EasyStarter, for example.
 
Which products are affected:
Library:  (FAST Motion Modules V2) L_CM1P_ControlModules
 
Short-term measures, Evaluation/recommendations:
Use the bit coding from the online help of parameter 0x500A:163.
 
 
Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201900197/1/
Contact form