L_TT1P_CrossCutter, L_TT1P_RegisterControl: Jump during correction (corrected from V3.16.0)

Corrected from:
Library:  L_TT1P_TechnologyModules_LM from V3.16.0.62 (update via Package Manager)
 
Response of the new version:
When the correction window is at a modulo overflow of the register position, there no longer occur any position jumps during the correction motion of the technology modules' mark correction.  
What happens?
The correction jumps to a starting position of approx. 1 - 5 % of the correction value and continues traversing via a 5th degree polynomial.
 
When does this behaviour occur?
Control via the technology module is active.
The correction window (lrLowerCorrPos. lrUpperCorrPos) is opened exactly at a modulo overflow of the master axis.
 
Which products are affected?
L_TT1P_CrossCutter and L_TT1P_RegisterControl from the L_TT1P_TechnologyModules_LM library (V3.15.0.32 and higher)
Short-term measures:
Parameterise the correction window (lrLowerCorrPos. lrUpperCorrPos) in such a way that it is not opened at a modulo overflow of the master axis. 
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700274/1/