Quick stop (QSP) is also executed when using the commissioning functions (from V1.5.6)

Function extension:
Now quick stop (QSP) is also considered and, if necessary, executed when using the commissioning functions rotation test mode and direction of rotation check (0x2825=1, =2, =4). The settings quick stop mode (0x605A) and quick stop deceleration (0x6085) are effective for ramping down. To ensure that the deceleration value set under 0x6085 in application units is correctly converted into a frequency ramp, the number of motor pole pairs (0x2C01:1) and the position resolution (0x608F:1) must be calculated or set correctly.

Contained in which products?
- i700 servo inverter from V01.05.06.9665

Application:
Moving or stopping the drive via QSP during commissioning or in the event of service using the commissioning functions.
 