Improvements on the axis bus

Which products are affected?
Inverter Drives 8400 TopLine from firmware version 12.00.00.00

Functional description
• Bus monitoring in the case of a data error or open circuit with an adjustable error response.
• Configurable exception handling for the received data if the drive is separated from the bus
• Increasing the baud rate from 500kbits to 800kbits makes it possible to repeat a telegram in the event of an error -> increase in error tolerance
• Individual IDs for cascade PDOs -> no mixing up of objects and simple diagnostics, e.g. by means of PCAN
• In C2444, an edge sensitivity for the bSetFail_DigOut input can be configured -> avoids the persistence of an error when establishing a signal ring

Applications
Error handling and diagnostics for applications with a horizontal setpoint coupling via the axis bus.