Eliminated from:
ECS power supply module ECSxE, operating system V5.0
Behaviour of the new version?
After being activated again, the CAN node guarding monitoring does not trip prematurely anymore. The internal timer is now correctly set to zero during deactivation.
Which products are affected?
ECS power supply module ECSxE, operating system <= V4.0
What happens?
The CAN node guarding monitoring trips prematurely once.
When does the problem occur?
After the CAN node guarding monitoring has been deactivated and then activated again, and in dependency of the value of an internal timer that, by mistake, has not been set to zero during deactivation.
Possible diagnostics?
None
Short-term measures/recommendations?
After one reset, the problem does not occur anymore.
Evaluation
Typically, the problem only occurs in association with the commissioning.