The L_DcSpeed_sToNorm_n function block yields wrong values on the output in connection with axis data from CAM data (elimination)

Which products are affected?
9400 HighLine axis controllers from Firmware version 05.00.30.00

Eliminated function restriction
The L_DcSpeed_sToNorm_n function block converts an angular difference signal to a scaled signal. A corresponding axis data structure is required for this (e.g. DI_AxisData, axis data from the L_CamProfiler or L_SdSetAxisData function block). If axis data were used that had been output via the L_CamProfiler function block on the XAxisData output the L_DcSpeed_sToNorm_n function block yielded a faulty signal whereas identical axis data that had been output via the L_SdSetAxisData function block yielded the correct result. This was due to a faulty conversion of the CAM data. One factor of converting _s in _n signals had not been considered. The conversion of CAM data has been revised to rule out the described function restriction. Now the L_DcSpeed_sToNorm_n function block can also be used in connection with axis data from CAM data and yields correct results.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200904091/1/