Inverted motor mounting position and incorrect display of velocity (remedied from V1.3 onwards)
Remedied from:
ECSxP Posi&Shaft V1.3 onwards
Behaviour of the new version?
The current velocity under C3053 is now indicated with the correct sign.
Which products are affected?
ECSxP Posi&Shaft <=V1.2
What happens?
The current velocity under C3053 is indicated inversely to the actual direction of movement of the machine. The amount is indicated correctly but the sign erroneously corresponds to one of the motor speed.
When does the problem occur?
If the inverted motor mounting position is selected (C3000 = 1).
Possible diagnostics?
In case of a movement in positive machine direction a negative velocity is indicated under C3053.
Short-term measures/recommendations?
None.
Evaluation:
No consequences on the correct functioning of the machine since only the value displayed is incorrect.
Published with service message No. 2007/02 and 2007/03