Positive edge of TouchProbe inputs TP6, TP7, TP8 cannot be evaluated with control cards Rev5 (solved)
Removed from:
9400 Highline V15.50.08, 9400 Servo PLC V09.50.08
Behavior of the new version:
The Touchprobe inputs can also be used without restriction with Rev 5 control cards.
Description of the behavior:
The behavior can be observed as follows:
As soon as the first rising edge has occurred at DigIn_x (x=6, 7, 8), the TPx_bTouchProbeReceived output changes to TRUE and remains until the device is restarted permanently TRUE. The TPx_dnTouchProbeTimeLag output begins to display permanently changed values or runs through endlessly.
Conditions under which the behavior occurs:
If the following conditions are met together:
The hardware version of the control card is C210_1 = BC
A CAN sync source C1120_0 = 1: CAN on board or 2: CAN module has been parameterized. Default is C1120_0 = 0.
The positive touch probe edge is to be evaluated : TPx_bEnablePosEdge of the respective touch probe system module (x = 6, 7, 8) is TRUE.
Affected products: 9400 Highline V15.50.07, 9400 Servo PLC V09.50.07 on devices with a revision 5 control card