Motor data: Input range of motor rated frequency (0x2C01:5) extended up to 2000 Hz (from V01.08.00)

Function extension:
'Motor rated frequency' (0x2C01:5):
The range of values that can be entered for the motor data parameter has been extended from the previous max. 1000 Hz to up to 2000 Hz.

Notes for clarification:
The input range of the 'Motor rated frequency' parameter does not determine the maximum achievable output frequency of the inverter. The motor rating data to be entered (rating plate data) are used for the internally used motor model to simulate the electrical motor characteristics. 
The actual maximum achievable output frequency of the inverter depends on other conditions, such as the maximum frequency limitation of the unit variant or the set switching frequency of the inverter. 
Even a motor with a lower rated motor frequency can be operated with output frequencies above its rated frequency (operation in field weakening).

Contained in which products?
Servo Inverter i950 FW: from V01.08.00

Application:
Applications with motors specially designed for high speeds, whose rated frequency is above 1000 Hz.