L_TS2P_FlexCAMState: If a Y-offset is used, the drive is moved to an incorrect disengagement position. (Corrected from V3.29.0)

Corrected from:
Library L_TS2P_TechModulesSynchronizingCamming (from V3.29.0)
Library L_TT1P_TechnologyModules_LM  (from V3.29.0)
(Update via Easy Package Manager)

Response of the new version:
The correct disengagement position is approached independently of a set offset.
 
What happens?

The disengagement position is not approached. 

When does the behaviour occur?

A disengagement position is set for the FlexCam technology module (TM) (scPar.lrSlaveSyncOutPos). In addition, an Y-offset has been set (lrSetOffsetPosY). When the function for disengaging is applied, the defined position is not reached by the offset. 

Which products are affected?

TM FlexCAM (L_TS2P_FlexCAMState from library L_TS2P_TechModulesSynchronizingCamming)

Short-term measures:
a. Before disengagement is activated, the offset can be set to 0 (lrSetOffsetPosY).

b. The FlexCAM technology module is disengaged via an absolute positioning to the desired disengagement position (e.g. MoveAbsolute)

Evaluation / recommendations:


Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202200391/1/