PROFINET / EtherCAT / EtherNet/IP: Fieldbus-specific IP addresses and parameterisations are lost after firmware update to V01.07.04 (corrected from V01.07.05)
Corrected from:
Servo Inverter i950 FW: from V01.07.05
Response of the new version:
When updating the firmware to V01.07.05, the remanently stored fieldbus-specific IP addresses, Profinet station names and parameterisations are now retained.
What happens?
When updating the firmware (FW update) to version V01.07.04, the remanently stored fieldbus-specific IP addresses, Profinet station names and parameterisations are lost. The default values are then effective, so that the units are typically no longer accessible from the master.
Affected parameters:
PROFINET: Station name (0x2381:004)
PROFINET: IP address (0x2381:001)
PROFINET: subnet mask (0x2381:002)
PROFINET: gateway address (0x2381:003)
PROFINET: I&M1-4 data (0x2381:005..009)
EtherCAT: SII EEPROM content, including Configured Station Alias
EtherNet/IP: IP configuration (parameter 0x23A1:005)