All TMs from L_TS2P: Position jump when xAbort and xSync are set simultaneously (corrected from V3.25.0)

Corrected from:
Library: L_TS2P_TechModulesSynchronizingCamming (from V3.25.0)
             (Update via Easy Package Manager)

Response of the new version:
If the functions xSyncPos = TRUE and xAbort = TRUE are set at the same time, the axis is kept at standstill. No coupling process is carried out.

What happens?
The position of the axis jumps to lrSetPosition = 0

When does the behaviour occur?
Two functions are assigned simultaneously in the same PLC cycle:
  • xSyncPos = TRUE
  • xAbort = TRUE 
Which products are affected?
L_TS2P_ElectronicGearboxBase from library L_TS2P_TechModulesSynchronizingCamming
L_TS2P_FlexCamState from library L_TS2P_TechModulesSynchronizingCamming
L_TS2P_FlyingSawState from library L_TS2P_TechModulesSynchronizingCamming
L_TS2P_SyncAndCorrectionState from library L_TS2P_TechModulesSynchronizingCamming
L_TS2P_CrossCutterState from library L_TS2P_TechModulesSynchronizingCamming

Short-term measures:
The function xSyncPos must not be assigned together with the function xAbort.

Evaluation / recommendations:
By considering the short-term measure, the described behaviour can be avoided in a simple way.