L_MC1P_BrakeGrindIn: Despite controller inhibit the motion axis remains in standstill status ( 0x500A.004=[3] ) (fixed from V03.24.00)
Corrected from:
Library: L_MC1P_MotionControlBasic (FAST Motion) from V03.24.00
(Update via Package Manager)
Response of the new version:
If the function Loop in brake cannot be executed due to the conditions mentioned below, the axis status is now correctly displayed with state 'disabled'.
What happens?
L_MC1P_BrakeGrindIn:
The Loop in brake function can only be started in the disabled state.
If the Loop in brake function cannot be executed due to the conditions mentioned below, the Loop in brake function will not be executed or it will be aborted, as expected.
After an abort, however, the 'Disabled' state is not displayed as the axis state, but the 'Standstill' state.
When does the behaviour occur?
When the Loop in brake function is activated, a Safe Stop 1 (SS1) or Quickstop application is requested.