L_TS2P_SyncAndCorrection: The reference value drifts with activated conductance correction (fixed as of V3.21.0)

Corrected from:
Library L_TS2P_TechModulesSynchronizingCamming V03.21.00.82
(Update via EASY Package Manager)

Response of the new version
The mark-corrected target position of the slave axis does not drift.
 
What happens?
The mark-corrected nominal position of the slave axis drifts.
 
When does the behaviour occur?
The master axis is at standstill. The controller is disabled.
The slave axis is coupled to the master axis with TM SyncAndCorrection.
 
Which products are affected?
Function block L_TS2P_SyncAndCorrectionState from library L_TS2P_TechModulesSynchronizingCamming
 
Short-term measures:
The slave axis must be locked together with the master axis.

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202000143/1/