PLC-Designer and LSPE: Connection aborted when uploading the safety parameter set via field bus (fixed from V01.04.02)

Corrected from:
Servo-Inverter i950 FW:   from V01.04.02.1546
 
Response of th new version:
No connection termination when uploading the safety parameter set via the LSPE integrated in the PLC Designer.
 
What happens?
As soon as the safety parameter set is to be uploaded via a fieldbus/controller using the LSPE integrated in PLC Designer, the message "Read parameter set from device failed" is displayed. The device must then be rebooted.

When does the behaviour occur?
When uploading the safety parameter set via the fieldbus, reproducibility 100%.
 
Which products are affected?
Servo-Inverter i950 FW
 
Short-term measures / Evaluation / Recommendations:
Do not upload the safety parameter set via the fieldbus, but via Ethernet/EASY Starter.