L_TS2P_SyncAndCorrection: Change of the gear factor correction leads to speed jumps (fixed since V3.20.0)

Corrected from:
L_TS2P_TechModulesSynchronizingCamming as of V03.20.00.60
(Update via Package Manager)
Response of the new version:
There are no speed jumps.
 
What happens?
Speed jumps occur.
 
When does the behaviour occur?
The maximum possible correction value of the gear factor correction is changed when the gear factor correction is activated.
 
Which products are affected:
Technology module L_TS2P_SyncAndCorrectionState from library L_TS2P_TechModulesSynchronizingCamming
 
Short-term measures:
First deactivate the gear factor correction and then change the value afterwards. The gear factor correction can then be reactivated.
 