L_UMTP: After update to V03.19.00 error message occurs due to wrong placeholder setting (corrected from V03.20.00)
Corrected from: Library: L_UMTP_Mathematics (FAST Motion) from V03.20.00.11
(Update via Package-Manager)
Response of the new version:
The placeholder setting has now been corrected and the described behavior no longer occurs.
What happens?
After updating an existing project to V03.19.00 the error message 'Could not open L_MC1P V03.19.00.999' appears when opening the project in PLC Designer. However, the project can still be compiled.
When does the behaviour occur?
After updating the libraries of an existing project to version V03.19.00. The reason for this error message is a wrong internal placeholder setting of the library 'L_UMTP_Mathematics' V03.19.00.68. Internally the library L_MC1P_MotionControlBasic in the not existing version V03.19.00.999 is attracted by placeholders. Actually the version L_MC1P_MotionControlBasic V03.19.00.101 is available.
Which products are affected? Library: L_UMTP_Mathematics (FAST Motion)
Short-term measures, Evaluation / Recommendations: Change the placeholder setting of the library L_UMTP manually to 'L_MC1P_MotionControlBasic' V03.19.00.101