Function extension: The "Initial value brake resistor overload" parameter C00122/2 can be used to select an initialisation value for the I2*t utilisation of the brake resistor (C00133).
Contained in which products?
Inverter Drives 8400 StateLine V21.00.00
Inverter Drives 8400 HighLine V21.00.00
Inverter Drives 8400 TopLine V21.00.00
Application: So far, the thermal brake resistor model has been initialised with 20°C when switching the mains for a hot brake resistor. With the "Initial value brake resistor overload" parameter C00122/2, you can select a new initialisation value.
Taxonomy:
8400 StateLine frequency inverters
,
8400 HighLine frequency inverters
,
8400 TopLine frequency inverters
AKB-ID:
201900249
Last update:
2023/09/09
Category:
Version Informations
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.