L_TT1P_RegisterControl: Undocumented error message 19504 (eliminated from V3.18.0)

Eliminated from:
Library: L_TT1P_TechnologyModules_LM from V03.18.0.33
                    (Update via Easy Package Manager)
 
Behaviour of new version:  
The undocumented 19504 error message no longer occurs. Instead, the user sees the error number 17174 (MarkCorrectionInNextCycle).
 
What happens?
When using the RegisterControl TM, the error message 19504 may occur. This error message is not documented.  
 
When does this behaviour occur?
The behaviour occurs when using the RegisterControl TM.
 
Which products are affected?
L_TT1P_RegisterControl technology module from the L_TT1P_TechnologyModules_LM library (V3.17.0.47 and higher)
 
Short-term measures:
Meaning of the error message: CorrectionInNextCycle
A mark error was reported during an active correction and will only be processed in the next correction window.
The mark position is within the correction window. If possible, parameterise the correction window in such a way that the mark position is outside the correction window.
 
Evaluation/recommendations:
As of control technology release V3.18, the error will be documented under the new error number 17174. 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201800191/1/
Contact form