EPM-S640, EPM-S650 at the CAN bus: Red MF LED lights up and the module cannot be put into operation

What happens?
The IO 1000 module cannot be put into operation The red MF Lead on the module lights up.
The parameters of the module look as follows:
- Baudrate: ? 
- Protocol: ?
- Data bits: 5
- Stop bit: Not defined
- Option 5: 0
- Option 6: 0
 
When does the behaviour occur?
The module EPM-S640 resp. EPM-S650 is inserted on the CAN bus of a Lenze Controller (PLC Desginer V3.x).
 
Which products are affected?
EPM-S640
EPM-S650
 
Short-term measures:
Set options 5 and 6 to the values specified in the IO 1000 system manual, e.g.:
- Option 5: 250
- Option 6: 1 
 
Set the baud rate, protocol, data bits, ... to the desired values. 
 
Hint: There is no change planned for this behaviour.
 
Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700165/1/
Contact form