L_TT1P_CrossCutter: Synchronous phase is limited to max. 50% (eliminated from V3.12)

Corrected from:
L_TT1P_TechnologyModules_LM V3.12.0.9

Response of the new version: 
The limitation has been removed.
_______________________________________________________________________________________________ 

What happens?
The INVALID_PARMETER_CUTTING_ANGLE error message is output.

 
When does this behaviour occur?
The behaviour occurs if the technology module is configured with a synchronous phase greater than 50%. For the L_TT1P_CrossCutter technology module, the synchronous phase is limited to max. 50%.
 
Which products are affected?
L_TT1P_CrossCutter function block from L_TT1P_TablePositioning_LM library (V3.9.0.62 and higher)
 
Short-term measures:
Only configure synchronous phases lower than 50%.
  
Evaluation/recommendations:
The function restriction is prioritised as high and will be dealt with in the next release.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500615/1/