Display parameter C1248/1 for current homing step

Function extension:

Depending on the selected homing mode, homing is effected in several steps. C1248/001 will now display which step is active.

The following homing steps are available for homing modes 4 - 15 and 100:

 

C1248/001:

0:         No action                       Initial step when changing to 'Homing' mode

1:         RefMark: Search                 Search run to homing pre-stop mark

2:         RefMark: Stop                   Stop when detecting homing pre-stop mark

3:         RefMark: Reversing             Reversing from homing pre-stop mark

4:         HW-Limit: Search                Search run to limit switch

5:         HW-Limit: Stop                  Stop when detecting limit switch

6:         HW-Limit: Reversing            Reversing from limit switch

7:         M-Limit: Search                    Search run until detection of torque limit

8:         M-Limit: Stop                      Detection of torque limit, tolerance time is running

9:         Reference: Search                  Search run to reference initiator

10:       Reference: Stop                     Stop when detecting reference initiator

11:       Reference: Offset                  Offset path run active

12:       Reference: Sequence profile          Sequence profile run after homing

13:       Reference: Position                    Homing to home position

14:       Reference: Cancellation              Homing cancelled

15:       End                                     Homing completed

 
Contained in which products?
  • Inverter Drives 8400 HighLine V16.00.00
  • Inverter Drives 8400 TopLine V16.00.00
 
Application:
Diagnostics of the current homing step. The parameter can be displayed in the 'Homing' dialog of the Engineer or in the monitor window.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500581/1/
Contact form