L_MC1P: IPC logbook in the controller: Response of following error monitoring function leads to multiple entries (corrected from V3.12.0)
Corrected from: - Library: L_MC1P_MotionControlBasic (FAST Motion) V03.12.00.70 (contained in PLC Designer V03.12.00.177 and higher)
Response of the new version: When the following error monitoring function responds, only one entry will be written to the IPC logbook of the controller.
What happens?
For an event, several identical entries (20503) are entered into the IPC logbook.
When does this behaviour occur?
The behaviour occurs when the following error monitoring function responds.
Which products are affected?
- Library: L_MC1P_MotionControlBasic (FAST Motion) (contained in the PLC Designer)
Short-term measures:
The information required to perform a fault analysis is available in the logbook. There are only more entries available than necessary.
Evaluation/recommendations: Fault analysis via the logbook entries is basically not impaired.