The L_EATP_Alarm_PackML function block can be used to trigger an alarm with an error response, e.g. 'Stop'. The alarm ID of the alarm can be read out via the Admin.StopReason.ID admin tag. If the alarm is acknowledged, Admin.StopReason.ID will be '0'.
What happens?
The Admin.StopReason.ID admin tag always returns '0'.
When does this behaviour occur?
Always
Which products are affected?
PLC Designer V3.8 and higher
ApplicationTemplate_PackML
Short-term measures:
None
Evaluation/recommendations:
In PLC projects, the Admin.StopReason.ID admin tag is used on the basis of the Application Template PackML. Due to the above function restriction, the Admin tag returns an incorrect value.
Taxonomy:
AT StartUp Project PackML
,
AT StartUp Project Standard
,
Lib L_EATP_ApplicationTemplate
,
Application Templates
AKB-ID:
201500354
Last update:
2023/09/09
Category:
Version Informations
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.