'Set actual position' function (0x2830=5) is not executed correctly if position resolution is not 16 bits (default) (corrected from V1.9.3)

Corrected from:
- i700 servo inverter V01.09.03.10964

Response of the new version:
In the future the setup position resolution will be calculated corerectly.
 
What happens?
The 'Set actual position' function (0x2830=5) is not executed correctly if a position resolution (0x608F:1 / 0x608F:2) other than the default is set.
When setting the actual position to the value selected via 0x2983/0x3183, the position resolution is not considered correctly (the 'shifting' for converting the position value via powers of two is carried out in the wrong direction).    
 
When does this behaviour occur?
The above-described problem occurs if the set position resolution (0x608F:1 / 0x608F:2) differs from the Lenze setting.  
Which products are affected?
- i700 servo inverter
 
Short-term measures:
Only use the 'Set actual position' function (0x2830=5) if the Lenze setting for the position resolution remains unchanged.  
 
Evaluation/recommendations:
Experience has shown that the position resolution only needs to be adapted for just a few applications to achieve the required drive characteristics.
Therefore, the described problem will only be relevant for a few applications.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500346/1/